FRU
OA — No outage required
GPSM — No outage required
NOTE:
For blade replacement: If the FRU failed in a way that made it unable to join the partition after the
failure, you might not need to shutdown the partition at the time of the replacement. The FRU can
be replaced and the firmware updated. When the partition is rebooted, the replacement FRU will
rejoin the partition.

I/O firmware

Every FlexLOM and mezzanine card supported requires its own UEFI driver and some also require card
specific ROM firmware.
For a complete list of supported I/O cards and related firmware, see the Firmware Matrix for HPE Integrity
Superdome X servers document at http://www.hpe.com/info/superdomeX-firmware-matrix.
The following are minimum required firmware versions for supported I/O cards.
90
I/O firmware
Process
1. Ensure the suspect OA is the standby OA; use the force
takeover command if needed.
2. Remove and replace the suspect OA.
3. Use the update firmware <uri> all command,
pointing it to the <uri> of a bundle file that matches what is
currently installed on the complex. This command check
the current firmware version of all installed FRUs and will
only update FRUs that do not match the complex firmware
version.
4. Check for indicts.
1. Ensure you are replacing the indicted GPSM.
2. Disconnect the cables from the GPSM being replaced.
3. Remove and replace the suspect GPSM.
4. Use the update firmware <uri> all command,
pointing it to the <uri> of a bundle file that matches what is
currently installed on the complex. This command check
the current firmware version of all installed FRUs and will
only update FRUs that do not match the complex firmware
version.
5. Check for indicts.
NOTE:
You will see indictments related to the loss of
redundancy of the CAMNet.
6. Acquit the indictments related to the loss of redundancy of
the CAMNet.

Hide quick links: