Subcomponent Isolation And Deconfiguration Displays - HP integrity superdome x Service Manual

Table of Contents

Advertisement

Alert ID: 2700420140317044214
Serial Num: 1X123456
Product Name: DDR3 DIMM
- Indicted / Acquitted -
Type Timestamp
Ind Mon Mar 17 04:42:10 2014
Acq Mon Mar 17 07:02:28 2014
---
- SubFru Isolation -
Entire FRU indicted.
---
- SubFru Deconfiguration -
Entire FRU deconfigured.
---
- Related Locations -
0x0100FF0100010A74 Path: dimm-1/1/0/1
0x0100FF01FF00FF11 Path: cpusocket-1/1/0
0x0100FF01FFFFFF94 Path: blade-1/1
---
--- end report --- 1 records shown

Subcomponent isolation and deconfiguration displays

Subcomponent isolation refers to the subcomponents of a part that can require service. In these cases,
the component is indicted because the only way the subcomponent can be serviced is by removing and
servicing the entire component.
Subcomponent deconfigurations are also possible. These are indications of subcomponent failures.
The show <location> and show fru command output might contain "SubFru Isolation" and "SubFru
Deconfiguration" sections to communicate subcomponent health information. If a subcomponent
deconfiguration event occurs, the corresponding subcomponent Isolation will also be set, which triggers
an indictment of the parent component.
The sections below show examples of how the subcomponent isolation sections look.
NOTE:
The format of the deconfiguration sections look identical to those for Isolation so are not shown in
the following sections.
Blade subcomponent displays
There are several different types of subcomponent displays which can be provided for blades.
DIMMs
The DIMM subFru Isolation display is different from other subFru Isolation displays in that it
communicates DIMM loading order issues rather than faults in the subFRUs. A "1" in the display below
means the DIMM is present but not used due to a loading order issue and "0" means there is no problem
with that DIMM location. This display along with the OA CLI show blade info command output can be
used to determine which DIMMs are present and which are associated with DIMM loading errors.
- SubFru Isolation -
- Blade -
- DIMM Loading Status -
24A
68
Subcomponent isolation and deconfiguration displays
Entity
CAE
User
CPU0: 1A - 6A - 19A - 24A
0
0
0
7B - 12B - 13B - 18B
0
0
0
2C -
5C - 20C - 23C
Reason
See reason above.
User request.
1
<- Indicates loading error for DIMM
(DIMMS 1A, 6A, 19A are OK)
0

Hide quick links: