Gas Supply; Electrical Supply; Water Supply - Falcon G2102 Installation And Servicing Instructions

Forced convection oven
Table of Contents

Advertisement

There must be no direct connection of the flue to any mechanical extraction system or the outside air. Open top
burners discharge combustion products directly into the room. Siting the appliance under a canopy is the ideal
arrangement.

1.4 GAS SUPPLY

The incoming service must be of sufficient size to supply full rate without excessive pressure drop.
connected to the service pipe by the Gas Supplier. Any existing meter should be checked by the Gas Supplier to
ensure the meter is of adequate capacity to pass the required rate of gas.
Installation pipe work should be fitted in accordance with IGE/UP/2. The pipe should be of adequate size but not
smaller than the gas inlet. Connections are as follows:
G2102 Range:
Rp3/4 (3/4" BSP female)
G2112 Oven:
Rp1/2 (1/2"BSP female)
An isolating cock must be located close to the appliance to allow shut-down during an emergency or servicing. The
installation must be tested for gas soundness and purged as specified in IGE/UP/1.
Note
The G2102 open top range is supplied complete with the necessary pipework for linking oven and open top burner
sections. The governor necessary for open top burners is incorporated in this pipework for Natural Gas operation,
and an extra governor must not be fitted to any of these appliances.

1.5 ELECTRICAL SUPPLY

The oven is equipped with a length of 3-core flexible cord for connecting to an electrical supply. A standard 13 amp
socket outlet can be used, in which case the plug must be fitted with a 3 amp fuse. If the supply is through a
distribution fuse box, it must be via a fuse having a maximum rating of 5 amp.

1.6 WATER SUPPLY

Not applicable to these appliances.
1.7 TOTAL GAS RATES -
Natural and Propane Gas
Model
kw (net)
G2102
50.8
G2112
19
G2112/2
38
1.7.1 Individual Burner Ratings -
Natural and Propane Gas
Burner type
kw (net) Bty/hr (gross)
Open top (x6)
5.3
oven
19
1.8 INJECTOR DIAMETERS - Natural & Propane Gas
Natural Gas Propane Gas
Open top
Ø1.92mm
Oven
Ø3.4mm
Oven Pilot
G29.2
Btu/hr (gross)
190,700
71,300
142,600
20,000
71,300
Ø1.2mm
Ø2.2mm
G24.1
A gas meter is