Back Panel - Electrolux ENV06 Service Manual

Ventilated, with electronic control
Hide thumbs Also See for ENV06:
Table of Contents

Advertisement

13.20 Back panel

1. Remove the worktop (see paragraph).
2. Remove the sides (see paragraph).
3. Unhook the tensioning spring.
4. In models with conductivity sensor, unfasten the
screw fixing the rear brush unit.
In models with temperature probes, unfasten
the screw fixing the pin guard.
5. Unfasten the screw fixing the bush to the drum
pin (models with conductivity sensor only).
6. On all models, use a screwdriver to remove the
snap ring and the spacing washer.
7. Disconnect the heating unit junction box (see
paragraph).
8. Disconnect the anti-disturbance filter
connectors (see paragraph).
9. Unfasten the 4 screws fixing the back panel to
the base, and the 2 screws fixing it to the
crossbars.
10. Remove the back panel, taking care that the
drum does not fall.
ADL 2010 / 01