INSTALLATION AND ANGLE ADJUSTMENT

3-

Wall Mounting

()
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
(2)
Using an allen key, remove the main unit from the base.
1
Loosen the
fixing screw
for the
base.
(3)
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
(4)
Connect the cable to the terminal block (see Step 3-3).
(5)
Mount the main unit onto the base.
1
Insert and
secure here.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
(6)
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up. Wait for
approximately 60 seconds.
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (3 ft.).
4
Pull out.
2
Open.
3
Unplug
the cable
connector.
Nylon
wire
loop
4
3
Close.
2
Connect the
connector.
3-2
Inside View of the Base
Wall mounting hole
Wall mounting hole
Bushing of wiring
hole (Φ18)
3-3
WIRING
POWER INPUT
TAMPER OUTPUT *
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
*: TAMPER terminals to be connected to a 24 hour supervisory loop.
Name
TROUBLE
OUTPUT
Tighten and
secure the
fixing screw
for the base.
TAMPER
OUTPUT
* UL-2: All relay outputs of Alarm/Trouble are resistive load only.
* UL-3: UL requires that the detector is to be connected to a UL listed Burglar power
supply Class 2, capable of providing a input range of not greater than  VDC – 6
VDC, 50 mA and battery standby time of 4 hours.
* UL-4: The equipment shall be installed in accordance with the National Electrical
Code, NFPA 70.
- 2 -
Base
Main unit connector
Wiring hole (M20 x .5)
Function
Trouble out is used for anti-masking signal. When
an object is placed close to the lens surface, for
a period of more than 00 seconds (approx.), the
IR anti-masking circuit will activate and generate a
trouble signal.
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
If the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected.
Waterproof seal
(Do not remove
this seal.)
Wiring terminals
Bushing of wiring
hole (Φ18)
Open wiring cap
Unit:mm
TROUBLE OUTPUT
SPARE
CREEP
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)