Top View; Side View - Optex SIP-3020/5 Installation Instructions Manual

Synthesized intelligent pir redwall-v series
Table of Contents

Advertisement

Applicable
SIP-3020/5
models

TOP VIEW

(Installation height 4.0 m (3ft.))
[ft.]
[m]
0
30
20
5
0
0
0
0
5
20
30
0

SIDE VIEW

(Installation height 4.0 m (3ft.))
[ft.]
[m]
3
4
0
2
0
0
0
0
0
0
20
30
40
50
Applicable
SIP-3020/5
models
TOP VIEW
(Installation height 2.3 m (7.6ft.))
[ft.]
[m]
0
30
20
5
0
0
0
0
5
20
30
0
SIDE VIEW
(Installation height 2.3 m (7.6ft.))
[ft.]
[m]
7.6
2.3
0
0
0
0
0
0
20
30
40
50
SIP-4010/5
SIP-404/5
: Near area
: Far area
: Creep zone
20
30
60
70
80
90
00
0
20
SIP-4010/5
SIP-404/5
: Near area
: Far area
: Creep zone
20
30
60
70
80
90
00
0
20
7
MASKING THE FAR AREA SENSOR
The far area mirror mounted in the main unit has 2 far masking
plates; one at the right side of this mirror and the other at the left
side of this mirror. You can mask the detection area by changing
the position of these masking plates.
Cautions>>
You can only mask the detection area from its outside to
its inside using the masking plates. You cannot mask only
the inside detection area.
However, if you need to mask the inside detection area
only, use the white space (margin) of the near area
masking seal (an accessory) for the masking. Attach the
seal and mask all mirrors that you need to shield.
Cautions>>
The window is linked to the main unit by nylon wire loop
so that the window does not fall. Do not pull the window
using excessive force.
After you have masked the detection areas, mount the
window and place the excessive nylon wire loop inside
the main unit.
How to remove the window>>
40 [m]
30 [ft.]
Applicable
models
1
Remove the masking plate from
the storage, and check the
detection area and the mirror you
use by referring to the area chart.
Far area mirror
Rib
7
50
40
30
5
0

40 [m]
30 [ft.]
- 8 -
Window
Press the left bottom hole with your
finger, and pull the window up.
SIP-3020/5
SIP-4010/5
2
Attach the masking plate to the mirror,
and secure it to the ribs.
3
Insert the fixing rubber form to secure
6
5
4
3
2
1
the knob of the masking plate.
20
0
0
0
20
30
5
0
5
0
7
2
6
3
5
4
If tree branches or other moving objects
are in the path of the detection beam.
SIP-404/5
Rib
40
50
[ft.]
5
[m]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sip-4010/5Sip-404/5

Table of Contents