Wall mounting is only permitted if the requirements for the housing, the installation
regulations, the clearance and separating regulations for the control cabinets or housings
are adhered to. The control cabinet cover or housing must be secured so that it can only be
opened with a tool. An appropriate strain-relief assembly for the cable must be used.
Wall mounting outside of the control cabinet or housing does not fulfill the requirements of
the FM approval.
Note
You must not install the device on a wall in hazardous areas.
To mount the device on a wall, you require the following:
● 4 wall plugs, 6 mm in diameter and 30 mm long
● 4 screws 3.5 mm in diameter and 40 mm long
To mount the device on a wall, follow the steps below:
1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawings (Page 45)".
2. Fit the connectors for the power supply. See also section "Power supply (Page 26)".
3. Insert the terminal block into the sockets on the device.
4. Screw the device to the wall.
Note
The wall mounting must be capable of supporting at least four times the weight of the device.