11.3.3.5
Service Setup
29. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
30. Pump down
Operate pump down operation
31. Dry concrete
Operate concrete curing operation.
Select Edit, set temp for every stage (1~99 1 is for 1 day).
Setting range is 25~55°C
When it is turned ON, dry concrete starts.
When it is 2 zone, it dries both zones.
32. Service contact
Able to set name & tel no. of contact
person when there is breakdown
etc. or client has trouble. (2 items)
Initial setting: Depend on model
17
Service setup
Pump down:
ON
Confirm
30°C
1
Service setup
Service contact:
Contact 1
Contact 2
Select