11.3.2.6
Network Adaptor Installation (Optional)
Remove the Control Board Cover, then
connect the cable included with this adaptor to
the CN-CNT connector on the printed circuit
board.
Pull the cable out of the Tank Unit so that
o
there is no pinching.
If an Optional PCB has been installed in the
o
Tank Unit, connect to the CN-CNT connector
of the Optional PCB.
Connection examples: H series
Without Optional PCB
Resistance (kΩ)
3.615
4.375
5.326
6.523
8.044
9.980
12.443
15.604
19.70
25.05
32.10
41.45
53.92
70.53
93.05
124.24
167.82
CN-CNT cable
For optional pump.
Power supply: AC230V/50Hz, <500W
Recommended part: Yonos 25/6: made by Wilo
For optional mixing valve.
Power supply: AC230V/50Hz (input open/output
close)
Operating time: 30s~120s
Recommended part: 167032: made by Caleffi
This section is for authorized and licensed electrician/water
system installer only. Work behind the front plate secured by
screws must only be carried out under supervision of qualified
contractor, installation engineer or service person.
Insert a flat head screwdriver into the slot on
the top of the adaptor and remove the cover.
Connect the other end of the CN-CNT cable
connector to the connector inside the adaptor.
79
WARNING
CN-CNT cable
With Optional PCB
Slot
Connector