Order No. MAC0011062C3 Room Air Conditioner CW-C180EF-W CW-C240EF CW-C180EF-M CW-SC180EF CONTENTS Page Page 1 Product Specifications 8 How to Install 2 Dimensions 9 Care and Maintenance 3 Wiring Diagram 10 Service Information 4 Refrigeration Cycle Diagram 11 Technical Data 5 Air Conditioner Performance Evaluation...
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 3 Wiring Diagram 3.1. CW-C180EF-W, CW-C180EF-M & CW-SC180EF. 3.1.1. Resistance of Fan Motor windings 3.1.2. Resistance of Compressor and the rated Capacitor. windings and the rated Capacitor. CW-C180EF-W CW-C180EF-W CW-C180EF-M CW-C180EF-M CW-SC180EF CW-SC180EF...
Page 5
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 3.2. CW-C240EF. 3.2.1. Resistance of Fan Motor windings 3.2.2. Resistance of Compressor and the rated Capacitor. windings and the rated Capacitor. CW-C240EF CW-C240EF Connection CWA921039 Connection 2JS438D4CA02 17.42 Ω 0.820 Ω Blue - Yellow 2.34 Ω...
Page 7
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF Trouble Check Result Cause Remedy • Air Swing Switch. • OFF position. • Open circuit. • Set it ON. Air Swing won’t run. • Resistance between • No contact at • Shorted or open circuit.
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 7.2. How to Operate. Open the Control Panel Cover. Fig. 1 Power Supply Switch off the breaker and set the Main Control Knob to the OFF position before connecting the power plug cord to an independent power supply.
• Some installation locations may require installation of a short-circuit breaker. • Time delay fuse or circuit breaker rating is 16 Amp. for CW-C180EF-W/M & CW-SC180EF and 25 Amp. for CW-C240EF. • Nominal cross sectional area of power supply wire must be 3 core x 2.0 mm or above (CW-C180EF-W/M &...
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 8.3. Installation Procedure. 8.3.1. Remove the Chassis Locking 8.3.4. Slide the Chassis back into the Bracket and screws. Cabinet. • Unscrew and remove the Chassis Locking Bracket from the front of the Cabinet. Remove the two screws from the rear of the Cabinet (For transportation purpose only).
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 8.3.7. Insert the Air Filter. 8.3.8. Attach the Front Intake Grille. • Slide the Front Intake Grille slightly to the right to attach it, then push down to secure it. 8.4. Removal of the Front Grille.
Page 13
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 8.5. Condensed Water Drainage. This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound. If the splashing sound annoys you, you can provide an outside drainage by using the following procedure which may, however, cause a small loss of performance.
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 9 Care and Maintenance Caution: Always turn off the air conditioner and the main power supply before unplugging the power cord to clean the unit. 9.1. Cleaning the Unit. 9.3. Cleaning the Air Filter.
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 10 Service Information 10.1. Removal of the Control Board 1. Remove the Front Intake Grille (refer to page 12). 2. Remove the Air Filter (refer to page 12). 3. Remove the Front Grille (refer to page 12).
CW-C180EF-W / CW-C240EF / CW-C180EF-M / CW-SC180EF 12 Exploded View (Note) • The above exploded view is for the purpose of parts disassembly and replacement. • The non-numbered parts are not kept as standard service parts.