Sub-Ring Configuration - Hirschmann RS20 Programming Manual

Industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Sub-Ring (RSR20, RSR30, MACH1000)

4.1.2 Sub-Ring configuration

Note: Avoid loops during the configuration phase. Configure all the devices
of the Sub-Ring individually. Before you connect the redundant line (close the
Sub-Ring), you must complete the configuration of all the devices of the Sub-
Ring.
Proceed as follows to configure the two Sub-Ring Managers of the example
constellation:
Select the Redundancy:Sub-Ring dialog.
Click on "Create".
Figure 20: Sub-Ring - New Entry dialog
Enter the value "1" as the ring ID of this Sub-Ring.
In the Module.Port field, enter the ID of the port (in the form X.X) that
connects the device to the Sub-Ring (in the example, 1.9). For the
connection port, you can use all the available ports that you have not
already configured as ring ports of the basis ring.
You have the option of entering a name for the Sub-Ring (in the
example, "Test").
48
4.1 Example configuration
Redundanz L2P
Release 5.0 04/09