OSEE PRM1014 User Manual page 63

Table of Contents

Advertisement

Use Cable1 to connect one of the CONTROL1/CONTROL2(RS422)
interface at the rear panel of TallyMan Controller with the RS485 Interface
of RMM1024, the functionality of the interfaces are as shown in the
following table.
 RS485(RMM1024): RJ45
The definition of RS485 interface of RMM1024 is as the same as in
TSI-3000-RMM1024 system, please refer to the above Table 5.1-13 for
the details, no repeat here.
 RS422(TallyMan Controller): DB9
Use one of the CONTROL1/CONTROL2 interface at the rear panel of
TallyMan
Controller
CONTROL1/CONTROL2 is a RS422 interface using female DB9
connector, and the pins of DB9 is defined as in Table 5.1-18:
Table 5.1-18 The Pins of CONTROL1/CONTROL2 in TallyMan Controller
PIN No.
DB9
1
0v/Chassis
2
Tx-
3
Rx+
4
0v
5
-
6
0v
7
Tx+
8
Rx-
9
0v
The connection should obey the rules below to set up the communication
between one of CONTROL1/CONTROL2 and RS485, as shown in Table
5.1-19:
Table 5.1-19 Connection Between CONTROL1/CONTROL2 of TallyMan
DB9(CONTROL1/CONTROL2) RJ45(RS485)
2
3
to
connect
Controller and RS485 of RMM1024
57 
Functionality of the Main Menu
with
RMM1024
Illustration
5
6
monitor,
the

Advertisement

Table of Contents
loading