The user manual applies to the following device types: PRM1014-3HSV PRM1014-HSV PRM1014-SV The images of PRM1014-3HSV are adopted in the following descriptions. Any of the different specifications between the device types are elaborated. Before reading the manual, please confirm the device type.
Overview Chapter 1 Overview PRM1014 is a 10.1”, single screen, high full HD portable monitor. It has a dedicate and simple outlook, and offers a full resolution 1920X1200 LCD panel, with wide viewing angle and wide color gamut. It supports the video signal of analog composite/3G/HD/SD-SDI and HDMI.
Page 8
Overview Functionality Audio phase meter and phase alarm display 16 channels embedded audio level meter, the channel number and the dB value can be displayed Supports various markers: Center Marker, Area Marker and Safety Marker Supports TSL/IMAGE VIDEO dynamic TALLY protocol ...
Safety Chapter 2 Safety FCC Caution Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 10
Safety Warnings: Read, keep and follow all of these instructions for your safety. Heed all warnings. Monitor Do not beat with a hard object or scratch the LCD display. Do not make the freeze picture displaying on the screen time too long, otherwise, it will leave the afterimage on the screen.
Page 11
Safety registers, stoves, or other apparatus (including amplifiers) that product heat. A nameplate indicating operating voltage, etc., is located on the rear panel. The socket-outlet shall be installed near the equipment and shall be easily accessible. Power Supply Cord ...
Chapter 3 Unpack and Installation Unpack: When unpacking the components of PRM1014 monitor, please verify that none of the components listed in Table 3.1 are damaged or lack. If there is any missing, contact your dealers or OSEE TECHNOLOGY CO., LTD. for it.
Page 14
Connect power source using the included power cord. Connect the power cord to the rear panel. Fasten the power protect accessory. As a final step, turn on each screen of the PRM1014 by pressing the corresponding power switch located on the front panel. 8 ...
Chapter 4 PRM1014 Features This chapter describes the features of PRM1014 monitor. The features of PRM1014 monitor are as shown in Figure 4-1 after installed and powered on: Figure 4-1 Features of PRM1014 Monitor Tally light: this LED light is at the top center of the front panel, and you can judge the monitor status by the color of Tally light.
Page 16
PRM1014 Features Center Marker: it is displayed in the center of the screen, and marks the center of the image. You can set whether to display it or not in MARKER menu. Audio Meter: it is displayed for audio monitoring. You can set its groups, direction, position and mode in AUDIO menu.
PRM1014 Features 4.1 Front Panel Features It will introduce the arrangement and the operations of the buttons in front of the panel in the following. 4.1.1 Arrangement of Front Panel There are a series of buttons at the bottom of the screen.
PRM1014 Features F2/∧ ENTER Power Tally Light(Front) Only the button has a light indicator. /MUTE 4.1.2 Operation of Front Panel The functionality and usage of the buttons at the front panel are as follows: Select the input signal. Press this button to display the source menu at the right top corner of the screen, as shown in Figure 4.1-2.
Page 19
PRM1014 Features Figure 4.1-3 Correspondence between Source Menu and Interface /MUTE This button can achieve the following two functions: : Audio monitor button. Toggle this button to enable or disable the audio monitor, and the light in the button will indicate the status of audio monitoring.
Page 20
PRM1014 Features Back to the higher level menu Quit the Main menu Refer to “5.2 Menu Settings” for detail about the main menu operations. Press and hold the MUTE+ENTER button for 3s can reset the menu settings to factory originals, as shown in Figure 4.1-5.
Page 21
PRM1014 Features MARKER, H/V DELAY, AUDIO METER, FAST MODE, TC, IMD, MUTE, PBP, CC, FREEZE, WIN SELECT, FOCUS ASSIST, LUMA ZOOM CHECK, UNDEF. Refer to "5.1.9 FUNCTION KEY Menu" for the details. F2/∧ This button can achieve the following two functions: ...
Page 22
PRM1014 Features selection. The relationship of the menu items and their range is shown in Table 4.1-1: Table 4.1-1 The Description of Adjust Menu Items Adjust Menu Description Range Default VOLUME Adjust the volume 0~31dB BRIGHTNESS Adjust the image brightness...
As shown in Figure 4.2-1, there are various input and output interfaces at the rear panel of PRM1014 monitor. Figure 4.2-1 The Rear Panel of PRM1014 Monitor The interfaces numbered from 1 to 8 in red dotted rectangle are described...
PRM1014 Features Battery Plate Tally Light(Back) Tally Switch 4.2.2 Operations of Rear Panel The details of these interfaces at the rear panel are described as follows: Video Input Interface (BNC) It provides two SDI input interfaces, one is labeled as SDI1 IN, and the other is SDI2 IN, 800mVp-p +/-10%.
Page 25
PRM1014 Features Pin No. Channel Value Pin 1 Pin 2 GREEN Pin 3~7 Pin 8 Tally light is in working status when grounding. IN/ OUT RS485 Interface (RJ-45) Support for dynamic UMD and updating the new firmware. The Comparison of Pins and Input/output connectors for RS485 is shown as in Table 4.2-2:...
Battery Plate It provides battery plate as optional accessory for PRM1014, thus, you can use external batteries as the power supply for PRM1014, and you can select two types according to the amount of the battery plates: one battery plate or two battery plates. Refer to “Chapter 7 Specifications” for the details about the optional accessories.
Functionality of the Main Menu Chapter 5 Functionality of the Main Menu This chapter describes the structure and functionality of the main menu, and introduces how to modify and customize the menu settings. The main menu includes the following menu items, as shown in Figure5-1. Figure 5-1 Main Menu 5.1 Main Menu Press the MENU button at the bottom of the front panel, the main menu is...
Page 30
Functionality of the Main Menu The menu interface is divided into three parts: Main Menu List: it contains the several sub-menu items. The title of this list is MAIN. Press Up(∧) or Down(∨) to access the corresponding menu item. Sub-menu value list: as shown in Figure 5.1-2, it lists the control icon, sub-menu item and the value of the item.
Functionality of the Main Menu when in the sub-menu item, it shows that this sub-menu item is selected, and the control icon is displayed as a yellow rectangle in front of it, as shown in Figure 5.1-4: Figure 5.1-4 A Sub-menu Item Is Selected ...
Page 32
NORMAL SCAN NORMAL OVER Show the scan mode. MODE UNDER FAST OFF/ON Show the fast mode. MODE Show screen SD ASPECT 16:9 16:9/4:3 Aspect Ratio. Show the production MODEL PRM1014-3HSV model. SERIAL PRM10142015010001 -- Show serial 26 ...
Functionality of the Main Menu Items Default Value Domain Range Description NUMBER number. 192.168.1.86 Show the IP address. ADDRESS Show color COLOR 2015-1-5.4 version according to VERSION its adjusted date. The sub-menu values in STATUS menu can’t be modified, they are displayed the actual status of the monitor.
Page 34
Functionality of the Main Menu Table 5.1-2 The Description of INPUT SELECT Menu Items Default Items Domain Range Description Value SDI1 ON/OFF Enable/Disable SDI1 input SDI2 ON/OFF Enable/Disable SDI2 input LINE1 ON/OFF Enable/Disable LINE1 input LINE2 ON/OFF Enable/Disable LINE2 input HDMI ON/OFF Enable/Disable HDMI input...
Functionality of the Main Menu The FOCUS ASSIST function is used to display images on the screen with sharpened edges to help camera focus operation. The sharpened edges are the compared area whose luminance is beyond the reference level, and the edges are displayed in the pointed color. For example, set the FOCUS COLOR as RED, and set the FOCUS LEVEL as 80, the compared results are as shown Figure 5.1-8: Figure 5.1-8 Illustration for FOCUS ASSIST Function...
Page 36
Functionality of the Main Menu Figure 5.1-10 MARKER Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-3: Table 5.1-3 The Description of MARKER Menu Items Default Items Domain Range Description Value Set whether to show all of the markers.
Page 37
Functionality of the Main Menu Default Items Domain Range Description Value scale: OFF: close area marker 16:9 Set whether to show the CENTER OFF/ON MARKER center marker Set the safety area size SAFETY according to the aspect ...
Page 38
Functionality of the Main Menu Marker Illustration Description This marker displays a rectangle to identify the SAFETY safety area with MARKER specified percentage. This marker displays multiple vertical horizontal lines to help CROSS HATCH when users check the composition of a picture. ...
Functionality of the Main Menu 5.1.4 AUDIO Menu The AUDIO menu items are used to adjust the audio parameters, the menu items are as shown in Figure 5.1-12: Figure 5.1-12 AUDIO Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-4: Table 5.1-4 The Description of AUDIO Menu Items Default...
Page 40
Functionality of the Main Menu Default Items Domain Range Description Value SELECT mode. Each G* contains four channels, and each CH* means a channel with number. G1+G2 G1+G3 G1+G4 G2+G3 G2+G4 G3+G4 ...
Page 41
Functionality of the Main Menu The appearance of Meter is as shown in Figure 5.1-13: Figure 5.1-13 Audio Meter METER SELECT and METER DIS MODE control the operational characteristics of Audio Metering, the former controls the amount of channels displayed in a meter. As shown in Figure 5.1-14, the meter displays at the left of the screen vertically, the METER SELECT is G1+G2, and the METER DIS MODE is MODE3, you can see the meter displays audio channel numbers and...
Functionality of the Main Menu Figure 5.1-15 the Positions of Meter Particularly, if the METER SELECT is G1-4, there will be 16 channels displayed in audio meter, and if the METER DIRECTION is Horizontal, the audio meter will display two meters separately on both sides of the screen.
Page 43
Functionality of the Main Menu Figure 5.1-17 DISPLAY SETUP Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-5: Table 5.1-5 The Description of DISPLAY SETUP Menu Items Default Items Domain Range Description Value Set whether to display STD information.
Page 44
Functionality of the Main Menu Default Items Domain Range Description Value LINE WAVE OFF/ON Set whether to show line wave. LINE WAVE shown Set the position of WFM. NUMBER Table 5.1-6. BOT RIGHT BOT LEFT Select the displayed position for WFM POS BOT RIGHT ...
Functionality of the Main Menu CONFIG Menu” for the details on PIP and PBP mode. Please refer to the international standard SMPTE2016-1-2007 for the details about AFD display. 5.1.6 CLOSED CAPTION Menu The CLOSED CAPTION menu items are used to adjust the parameters displayed on the screen, the menu items are as shown in Figure 5.1-18: Figure 5.1-18 CLOSED CAPTION Menu The relationship of Items, Default Value, Domain Range and Description...
Functionality of the Main Menu 5.1.7 CONFIG Menu The CONFIG menu items are used to adjust the parameters defined by customers, the menu items are as shown in Figure 5.1-19: Figure 5.1-19 CONFIG Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-8: Table 5.1-8 The Description of CONFIG Menu Items Default...
Page 47
Functionality of the Main Menu Default Items Domain Range Description Value bottom left BOT RIGHT: bottom right TOP RIGHT TOP LEFT BACK LIGHT 0~30 Adjust the back light Set whether open the AUTO STANDBY OFF OFF/ON standby mode. picture APPERTURE 0~24...
Page 48
Functionality of the Main Menu picture and the slave picture is as shown in Figure 5.1-21: Figure 5.1-21 The Position Relationship in PIP Mode And you can adjust the display size by the PIP SIZE item, and there are two kinds of outlines for the slave picture, as shown in Figure 5.1-22: Figure 5.1-22 The Size for the Slave Picture In PIP mode, if you set SUB IN SELECT to be WAVE FORM, it displays the WFM in the position of the slave picture, and the content of the slave...
Page 49
Functionality of the Main Menu PBP(Picture by Picture) The two pictures generated by two input signals separately are displayed side by side, and this function helps with white balance adjustment, and determining shooting angles between two cameras etc. In PBP mode, the size of the main picture is as large as the slave picture’s, and the position relationship of the main picture and the slave picture is as shown Figure 5.1-24: Figure 5.1-24 PBP Mode...
Page 50
Functionality of the Main Menu Method 2: By function key. Set PBP function to a function key (F1~F5). Select the menu item FUNCTION KEY F1 for example, and assign its sub-item value as PBP, as shown in Figure 5.1-26: FUNCTION WIN SELECT MAIN...
Functionality of the Main Menu Figure 5.1-27 Entering the Auto Standby Mode When detecting no signal input or signal disappeared, the power indicator will be lit in flash green for 10 seconds, and showing the standby prompt, after that, the monitor screen will be turned off, and it will be in auto standby mode, the POWER indicator is lit in green.
Page 52
Functionality of the Main Menu Figure 5.1-28 COLOR TEMP Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-10: Table 5.1-10 The Description of COLOR TEMP Menu Items Items Default Value Domain Range Description USER1: ...
Functionality of the Main Menu Items Default Value Domain Range Description D65:6500K D93:9300K Reset the Gain and RESET Offset values to the product originals COLOR OFF/EBU/SMPTE-C/ Select the color matrix SPACE ITU-709/AUTO The items about RED/GREEN/BLUE GAIN and BIAS are available only in USER1 and USER2 mode.
Page 54
Functionality of the Main Menu of the sub-item is shown in Table 5.1-11: Table 5.1-11 The Description of FUNCTION KEY Menu Items Items Default Value Domain Range Description SCAN, NATIVE, ASPECT, BLUE ONLY, MONO, MARKER, H/V DELAY, AUDIO METER, FAST Set a function to SCAN MODE, TC, IMD, MUTE, PBP,...
Functionality of the Main Menu Press F1, F2 button to activate the assigned function and adjust the parameter value. The SCAN mode or the ASPECT mode is not selectable when Native mode is set to ON. Particularly, when the PBP function is assigned to a function key, press this function key to select the display mode for picture &...
Page 56
Functionality of the Main Menu Default Items Domain Range Description Value YELLOW WHITE string displayed on the screen. After entering this item, XXXXXXXX -- CHARACTER press Up or Down to choose your character for this IMD string. LOCAL ...
Page 57
12 Chinese characters. For other values of IMD PROTOCAL, the IMD CHARACTER abides by the corresponding protocol. The PRM1014 monitor could receive the Tally control signal from a TSL server, and display the Tally information on PRM1014 through the LED tally and OSD tally.
Page 58
Functionality of the Main Menu We recommend the following two methods according to the different interface of TSI-3000 which is selected to connect with RMM1024. METHOD1 Use the COM7~COM12 interface of TSI-3000 to connect with RMM1024 Cable1 Use Cable1 to connect one of the COM7~COM12 interface at the rear panel of TSI-3000 with the RS485 Interface of RMM1024, the functionality of the interfaces are as shown in the following table.
Page 59
Functionality of the Main Menu PIN No. Illustration Tx+(data to external device) GND(Tx Data Common) GND(Rx Data Common) Rx+(data from external device) Tx-(data to external device) The connection should obey the rules below to set up the communication between one of COM7~COM12 and RS485, as shown in Table 5.1-15: Table 5.1-15 Connection Between COM7~COM12 of TSI-3000 and RS485 of RMM1024 DB9(COM7~COM12) RJ45(RS485)
Page 60
Functionality of the Main Menu Figure 5.1-33 Pin Sequence of Cable1 METHOD2 Use the COM3~COM6 interface of TSI-3000 to connect with RMM1024 Cable1 Use Cable1 to connect one of the COM3~COM6 interface at the rear panel of TSI-3000 with the RS485 Interface of RMM1024, the functionality of the interfaces are as shown in the following table.
Page 61
Functionality of the Main Menu Table 5.1-16 The Pins of COM* in TSI-3000 PIN No. 6P6C Illustration Rx-(data from external device) GND(Data Common) Tx+(data to external device) Tx-(data to external device) Not connected Rx+(data from external device) The connection should obey the rules below to set up the communication between one of COM3~COM6 and RS485, as shown in Table 5.1-17: Table 5.1-17 Connection Between COM3~COM6 of TSI-3000 and RS485 of RMM1024...
Page 62
Functionality of the Main Menu The pin sequence should be defined as in Figure 5.1-35: Figure 5.1-35 Pin Sequence of Cable1 TallyMan--RMM1024 Connect the TallyMan Controller TM1/TM2/TM2 PLUS with RMM1024, as shown in Figure 5.1-36: Figure 5.1-36 TSL Server and Display Monitor ...
Page 63
Functionality of the Main Menu Use Cable1 to connect one of the CONTROL1/CONTROL2(RS422) interface at the rear panel of TallyMan Controller with the RS485 Interface of RMM1024, the functionality of the interfaces are as shown in the following table. RS485(RMM1024): RJ45 The definition of RS485 interface of RMM1024 is as the same as in TSI-3000-RMM1024 system, please refer to the above Table 5.1-13 for the details, no repeat here.
Page 64
Functionality of the Main Menu DB9(CONTROL1/CONTROL2) RJ45(RS485) TSL TallyMan Controller TM1, TSL TallyMan Controller TM2, TSL TallyMan Controller TM2 PLUS all comfort to the above definition about the connection and the pins relationship. Refer to the user manuals of these devices for details.
Page 65
Functionality of the Main Menu Figure 5.1-38 Pin Sequence of Cable1 Cable2 Use Cable2 to connect every two RMM1024 monitors through the RS485 Interface, the Cable2 is a straight through line, and the connectors at the two ends of Cable2 should both be male RJ45. The pin sequence of Cable2 should be defined as in Figure 5.1-39: 59 ...
Page 66
Figure 5.1-39 Pin Sequence of Cable2 5.1.10.2 IMD Settings The position of Tally display on the PRM1014 monitor is as shown in Figure 5.1-40. The LED Tally indicator is displayed at the top center of the monitor, and the two OSD Tally lights are displayed at the bottom of the monitor screen, separately at the left and right side of the IMD characters.
Page 67
Functionality of the Main Menu Figure 5.1-40 Tally Display When receiving data of TSL3.1 or TSL4.0 protocol, we support the data length to be 0~126 and 128~254. When the data is in 128~254, the result will be equal to subtract 128 from the IMD ID, in addition, the data length is 0~255 when receiving data of MAGE VIDEO protocol.
Page 68
Functionality of the Main Menu IMD Items Items Value Description DISPLAY TSL3.1 it could receive the data of TSL4.0 protocol PROTOCAL IMD ID BAUD 38400 RATE It will display as the result of OR relationship of LEFT OSD Tally and RIGHT OSD Tally.
Page 69
Functionality of the Main Menu Items Value Description IMD DISPLAY IMD PROTOCAL TSL4.0 IMD ID BAUD RATE 38400 It will display as the result of OR relationship of LEFT OSD Tally and RIGHT OSD Tally. When only one of the two lights is lit, the LED Tally will light in the same LED TALLY color as the lit OSD Tally’s, otherwise, when the two lights of OSD Tally are lit, the LED Tally will light in...
Functionality of the Main Menu Items Value Description BAUD RATE 38400 It will display as the result of OR relationship of LEFT OSD Tally and RIGHT OSD Tally. When only one of the two lights is lit, the LED Tally will light in the same color as the lit OSD Tally’s, LED TALLY otherwise, when the two lights of OSD Tally are...
Page 71
Functionality of the Main Menu Display the Main Menu Press MENU button to enter into the main menu, it displays at the top left corner of the screen. Switch menu items After displaying the main menu, press ∧(Up) or ∨(Down) button to choose a menu item, the menu item selected is in yellow.
Page 72
Functionality of the Main Menu according to the current selected menu item. Switch sub-menu items After displaying the sub-menu items list, press ENTER button to enter into the sub-menu items list, press ∧(Up) or ∨(Down) button to choose a sub-menu item, a yellow rectangle is in front of the selected sub-menu item.
Page 73
Functionality of the Main Menu You can select one of languages (English or Chinese) for displaying the menu. The default language for the menu is ENGLISH. The following will teach you how to switch to Chinese. Operation: Step 1 Select CONFIG menu Press MENU button to display the OSD menu, click ∨(down) button to select CONFIG menu.
Page 74
Functionality of the Main Menu SDI1 Figure 5.2-4 Switching the Value of LANGUAGE Step 4 Exit the main menu Click MENU button to exit the main menu. 68 ...
The network address of the computer which is connected with PRM1014 and the network address of PRM1014 must be in the same segment. This chapter will introduce how to set and check the parameters of PRM1014 in Internet Explorer.
Network Control 6.2 Menu Control Open the management interface as shown in Figure 6.2-1, the menu items listed in the left part are almost as the same as the main menu items. Figure 6.2-1 Management Interface As shown in Figure 6.2-1, the management interface is divided into the following parts: Input Source Selection Button It is used to selecting an input source as the input signal, such as: SDI1,...
Page 77
Network Control Parameter list It shows the parameter names, values and operation buttons of the selected navigation menu, as shown in the red rectangle in Figure 6.2-2. The title in the yellow rectangle of the parameter list and the parameter list will change with the navigation menu when switched.
Network Control 6.2.1 ADJUST Menu It will introduce ADJUST menu. Click ADJUST button at the left navigation menu list, it will display the adjust parameters, as shown in Figure 6.2-3: Figure 6.2-3 ADJUST Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 6.2-1: Table 6.2-1 The Description of ADJUST Menu Items Items...
Network Control Items Default Value Domain Range Description normal mode is actually the color mode Display synchronizing H DELAY H/V DELAY signals in horizontal or V DELAY vertical mode H/V DELAY Current Audio Level Current Audio Enable/disable the audio MUTE Level monitor MUTE...
Network Control NORMAL SCAN NORMAL OVERSCAN Set the scan mode UNDERSCAN Whether to display NATIVE OFF/ON the picture dot by dot 6.2.3 SYSTEM Menu It will introduce SYSTEM menu. Click SYSTEM button at the left navigation menu list, it will display the system parameters, as shown in Figure 6.2-5: Figure 6.2-5 System Menu The relationship of Items, Default Value, Domain Range and Description...
Network Control Domain Items Default Value Description Range LOCK NUMBER 0001 Serial Number 32626 Version Product information FPGA Version Product information F107 Version Product information 6.2.4 Other Menus For the menu items in management interface are almost as the same as the menu items in the Main menu on screen, there will be no further description about their meanings and value range in this chapter, refer to “Chapter 5 Functionality of the Main Menu”...
Page 82
Network Control Figure 6.3-1 Parameter List for AUDIO Figure 6.3-2 Screen Main Menu for AUDIO Click button to display the drop-down value list for the parameter, as shown in Figure 6.3-3, for example, modify “CH1-2” to “G1”. Figure 6.3-3 Display the Drop Down Value List of Meter Select(S) Click button to confirm the selection and the page is refreshed.
Page 83
Network Control Figure 6.3-4 Modify the Value of a Parameter The volume can be checked and modified in adjust menu on screen adjustment, or in Volume item of ADJUST menu in management interface. Figure 6.3-5 The Value is Modified Simultaneously on Screen Menu Likewise, if you modify the value of a parameter on screen menu first, you may check the same changing result in management interface through network connection.
Page 88
Specifications Figure 7-3 Top View(Unit: mm) Figure 7-4 Side View(Unit: mm) Specifications are subject to change without notice. ------------------No Text Below------------------ 82 ...
Page 89
FOR MORE INFORMATION PLEASE VISIT: http://www.osee-dig.com/ OSEE TECHNOLOGY CO., LTD. No.22 Building, No.68 zone, Beiqing Road, Haidian District, Beijing, China Tel: (+86) 010-62434168, Fax: (+86) 010-62434169 E-mail: sales@osee-dig.com...