General Mounting Instructions - Hatteland HD 08T21 STD-***-F SERIES User Manual

Series x - standard display
Table of Contents

Advertisement

General Installation Recommendations
D: General rule for console mounted units:
To ensure proper cooling airflow, long-life and stable operation for all units, please make sure that the
console casing have either fans or decent ventilation holes to prevent overheating inside the console due to
the combined temperature of both Display or Panel Computer units together with other electronic instruments.
A general rule is to make sure the console casing is capable of expelling "worst case scenario" in respect of
the "Max Power Consumption" of all devices installed. Please review also point 2, 5, 6 and 9 (previous
section) for additional information and installation tips.
Note that 24" and 26" Panel Computer units have their own internal fans. See point A for more information.

General mounting instructions

1. The useful life of the components of all Electronics Units generally decreases with increasing ambient temperature;
it is therefore advisable to install such units in air-conditioned rooms. If there are no such facilities these rooms
must at least be dry, adequately ventilated and kept at a suitable temperature in order to prevent the formation of
condensation inside the display unit.
2. With most Electronic Units, cooling takes place via the surface of the casing. The cooling must not be impaired by
partial covering of the unit or by installation of the unit in a confined cabinet.
3. In the area of the wheel house, the distance of each electronics unit from the magnetic standard compass or the
magnetic steering compass must not be less than the permitted magnetic protection distance. This distance is
measured from the centre of the magnetic system of the compass to the nearest point on the corresponding unit
concerned.
4. Units which are to be used on the bridge wing must be installed inside the "wing control console" protected against
the weather. In order to avoid misting of the viewing screen, a 25 ... 50 W console-heating (power depending on the
volume) is recommended.
5. When selecting the site of a display unit, the maximum cable lengths have to be considered.
6. When a product is being installed, the surface base or bulkhead must be checked to ensure that it is flat in order to
avoid twisting of the unit when the fixing screws are tightened, because such twisting would impair mechanical
functions. Any unevenness should be compensated for by means of spacing-washers.
7. This Product shall be grounded to protective Earth. For AC Power cables this is done trough the ground wire in the
connector, for DC input the ground bolt shall be used. A shorter and thicker cable gives better grounding. A 6mm²
is recommended, but a 4mm² or even 2.5mm² can be used for this purpose
8. Transportation damage, even if apparently insignificant at first glance, must immediately be examined and be
reported to the freight carrier. The moment of setting-to-work of the equipment is too late, not only for reporting the
damage but also for the supply of replacements.
9. The classification is only valid for approved mounting brackets provided by Hatteland Display. The unit shall be
mounted stand-alone without any devices or loose parts placed at or nearby the unit. Any other type of mounting
might require test and re-classification.
Installation
IND100078-29
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd 13t21 std-***-f series

Table of Contents