10
MENU
Pump Menu: Settings
SETTINGS

Setting Password

1. Check that the green power LED is on.
2. Press Menu. Press Select to select "Settings".
3. Use the Up or Down arrow to scroll to "Device".
4. Press Select.
5. Press Up or Down arrow to scroll to "Password". The
default setting is "Disabled".
6. Press Select.
7. Press Up or Down arrow to change the setting to
"Enabled". Press Save to save.
8. Press the Down arrow. "Password Timeout" will be
displayed. The factory default time is 1 minute. This
means the pump will go into Password Protection
mode 1 minute after the last control panel key is
pressed.
9. Press Select to change time setting from 1 minute
to 6 hours and press Save to save.
10. Press the Down arrow and then press Select on
"Enter Password" to change the setting.
11. Press the Left or Right arrows to move cursor and
press the Up or Down arrow to change the password
number to desired setting.
12. Press Save to save. To cancel any changes, press
Back to exit without saving.
Entering Password
1. Press any button (besides the speed button) to
prompt the screen for a password.
2. To enter password, use the Left and Right arrows to
move the cursor and the Up and Down arrow button
to scroll through the digit then press Save to confirm.
®
INTELLIPRO
2 VST Variable Speed Pump Installation and User's Guide
MENU
SPEED 1-8
Pump Menu: Speeds 1-8

Pump Operating Modes

®
The IntelliPro
2 VST Variable Speed Pump can be
programmed in three different modes:
Manual, Schedule, and Egg Timer. Speeds 1-4 can
be programmed in all three modes. Speeds 5-8 can
only be programmed in Schedule mode since there are
no buttons on the control panel for Speeds 5-8. The
default setting for Speeds 5-8 is "Disabled".
Speed 1 (1-4)
Schedule
Egg Timer
Speed 5 (5-8)
Schedule
Speed Menu Tree Options
Manual
Assigns a speed to one of the four Speed buttons
on the control panel. This mode can only be used for
speeds 1-4. Speeds 1 and 2 are Manual by default.
To operate in Manual mode, press one of the four
speed buttons and then press the Start/Stop button.
The pump will run the assigned speed for that speed
button.
Egg Timer
Speeds 1-4 can be programmed to run for a duration
of time once a speed button is pressed.
Speeds 3 and 4 are Egg Timers by default. This
prevents the pump from running at a speed higher
than half of the maximum speed indefinitely. If you
desire a different method of operation, speeds 3 and 4
can be changed to Manual mode in the control menu.
To operate in Egg Timer mode, press a speed
button and then press Start/Stop. The pump will run
that speed for the set amount of time and then turn off.
Schedule
Program speeds 1-8 start and stop at a specific time
during a 24 hour period. Speeds programmed in
Schedule mode will override any manually selected
speed once the next Schedule command commences.
Manual
Set Speed - Defa
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
Disabled
Default: Disabled
Set Speed
Set Start Time
Set Stop Time

Hide quick links: