Control Panel: Pump Menu Guide - STA-RITE INTELLIPRO 2 VST Installation And User Manual

Variable speed pump
Table of Contents

Advertisement

Operator Control Panel: Pump Menu Guide
MENU
Press MENU button to access menus
SETTINGS
Set Date and Time
(pages 8-10)
Set Speed Max/Min
Alarm Log (1-10)
SPEED 1-8
Speed 1-4
(pages 10-12)
Speed 5-8
EXT CONTROL
(page 12)
FEATURES
(page 13)
Quick Clean
PRIMING
Disabled/Enabled
(pages 13-15)
Priming Speed
Max Priming Time
Priming Range
Priming Delay
THERMAL MODE
Disabled/Enabled
(page 16)
Set Speed
Pump Temperature
Date
Time
Hour Format
Min Speed (450-1700 RPM) - Default: 450 RPM
Max Speed (1900-3450 RPM) - Default: 3450 RPM
Device
Pump Address (1-16) - Default: 1
Screen Contrast (1-5) - Default: 3
Language
Temperature Unit
Password
Firmware Version
Manual
Schedule
Egg Timer
Disabled
Schedule
Program 1
Set Speed (450-3450 RPM) - Default: 750 RPM
Stop Delay (0 min. to 10 min.) Default: 0 minutes
Program 2
Set Speed (450-3450 RPM) - Default: 1500 RPM
Stop Delay (0 min. to 10 min.) Default: 0 minutes
Program 3
Set Speed (450-3450 RPM) - Default: 2350 RPM
Stop Delay (0 min. to 10 min.) Default: 0 minutes
Program 4
Set Speed (450-3450 RPM) - Default: 3110 RPM
Stop Delay (0 min. to 10 min.) Default: 0 minutes
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Time Out
Set Speed (450-3450 RPM) Default: 3450 RPM
Quick Clean Duration (1 min. to 10 hrs.) Default: 10 minutes
Disabled / Enabled - Default: Enabled
Set Speed (2400-3450 RPM) - Default: 3450 RPM
(1 min. to 30 min.) Default: 11 minutes
(1 - 10) Default: 5
(1 sec. to 10 min.) Default: 20 seconds
Disabled / Enabled - Default: Enabled
Set Speed (450 RPM - 3450 RPM) Default 1000 RPM
40° F - 50° F (4.4° C through 10° C) Default: 40° F (4.4° C)
Months (1-12)
Days (1-31)
Years (2000-2050 Plus)
Hours (24hr Mode: 0-23) (12hr Mode: 1-12 AM & PM)
Minutes (0-60)
AM/PM - Default: AM/PM
24 Hour
English - Default: English
Português
Deutsch
Italiano
Nederlands
Español
Français
Fahrenheit - Default F°
Celsius C°
Disabled - Default: Disabled
Enabled
Password Timeout (1 min. to 6 hrs.) - Default: 1 minute
Set Password (0000 - 9999) - Default: 1234
Set Speed - Default Spd 1-2: Manual
Set Speed
Set Start Time
Set Stop Time
Set Speed - Default Spd 3-4: Egg Timer
Time
Default: Disabled
Set Speed
Set Start Time
Set Stop Time
®
INTELLIPRO
2 VST Variable Speed Pump Installation and User's Guide
7

Hide quick links: