STA-RITE Supermax Installation And User Manual

STA-RITE Supermax Installation And User Manual

High performance pump
Hide thumbs Also See for Supermax:

Advertisement

PUMP WARNINGS AND SAFETY INSTRUCTIONS
(Pentair Water Pool and Spa
FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY
INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL
SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE
WARNINGS AND ALL INSTRUCTIONS IN THE OWNER'S MANUAL BEFORE USING THIS PUMP. THESE
WARNINGS AND THE OWNER'S MANUAL MUST BE LEFT WITH THE POOL OWNER.
Warnings and safety instructions for Pentair Water Pool and Spa® pumps and other related products are
available at: http://www.pentairpool.com/pool-owner/safety-warnings/ Call (800) 831-7133 for additional
free copies of these instructions. Please refer to www.pentairpool.com for more information related to
Pentair Water Pool and Spa® pumps.
SUCTION ENTRAPMENT HAZARD: STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION
OUTLETS!
THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE
MAIN DRAIN AT THE BOTTOM OF YOUR POOL AND SPA. THIS SUCTION IS SO STRONG THAT IT CAN
TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO A POOL OR
SPA DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.
THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING,
CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAP-
MENT, EVISCERATION AND/OR DEATH.
The suction at a pool or spa drain or outlet can cause:
Limb Entrapment: When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This
hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.
Hair Entanglement: When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This hazard is
present when the flow rating of the cover is too small for the pump or pumps.
Body Entrapment: When a portion of the body is held against the drain cover trapping the swimmer underwater. This
hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or
pumps.
Evisceration/Disembowelment: When a person sits on an open pool (particularly a child wading pool) or spa outlet and
suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover
is missing, loose, cracked, or not properly secured.
Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an
outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly
secured.
NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL
CODES FOR SWIMMING POOLS, SPAS AND HOT TUBS, INCLUDING NSPI STANDARDS AND CPSC GUIDELINES.
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
© 2010 Pentair Water Pool and Spa, Inc. All rights reserved - Sta-Rite® , Pentair Pool Products® and Pentair Water Pool and Spa® is a registered
trademark of Pentair Water Pool and Spa, Inc. Technical Support: (800) 831-7133
P/N 356476 Rev A (08-13-10)
Pentair Water Pool and Spa
For Pool and Spa
Pumps (Non SVRS Pumps)
®
®
, Sta-Rite
, and Pentair Pool Products
1
®
®
)
*356476*

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Supermax and is the answer not in the manual?

Questions and answers

Summary of Contents for STA-RITE Supermax

  • Page 1 CODES FOR SWIMMING POOLS, SPAS AND HOT TUBS, INCLUDING NSPI STANDARDS AND CPSC GUIDELINES. READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE © 2010 Pentair Water Pool and Spa, Inc. All rights reserved - Sta-Rite® , Pentair Pool Products® and Pentair Water Pool and Spa® is a registered *356476* trademark of Pentair Water Pool and Spa, Inc.
  • Page 2 PUMP (Non SVRS) WARNINGS AND SAFETY INSTRUCTIONS TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD: • Pools and spas should utilize a minimum of two drains per pump. • A properly installed and secured ANSI/ASME A112.19.8 approved anti-entrapment suction cover must be used for each drain.
  • Page 3 ® SuperMax High Performance Pump Installation User's Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...
  • Page 4: Customer Service

    This document is subject to change without notice. 1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000 Trademarks and Disclaimers: SuperMax ® , Pentair Pool Products ®...
  • Page 5: Table Of Contents

    Table of Contents Important Warning and Safety Instructions ................ii Section 1: Introduction ......................1 SuperMax Pump Overview ..................1 ® General Features .....................2 Section 2: Electrical Requirements ..................3 Wiring Installation .....................3 Section 3: Maintenance .....................5 Pump Strainer Basket ....................5 Cleaning the Pump Strainer Basket .................5 Winterizing .......................7...
  • Page 6 ® http://www.pentairpool.com/pool-owner/safety-warnings/ or call (800) 831-7133 for additional free copies of these instructions. Please refer to http://www.pentairpool.com/pool-owner/safety-warnings/ for warning and safety instructions related to the SuperMax High Performance Pump. ® READ AND FOLLOW ALL WARNING AND SAFETY INSTRUCTIONS This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
  • Page 7 Pentair Water Pool and Spa ® PUMP WARNING AND SAFETY INSTRUCTIONS For Pool and Spa Pumps (Non SVRS Pumps) (Pentair Water Pool and Spa , Sta-Rite , and Pentair Pool Products ® ® ® THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAPMENT, EVISCERATION AND/OR DEATH.
  • Page 8 Pentair Water Pool and Spa ® PUMP WARNING AND SAFETY INSTRUCTIONS For Pool and Spa Pumps (Non SVRS Pumps) (Pentair Water Pool and Spa , Sta-Rite , and Pentair Pool Products ® ® ® The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new requirements for owners and operators of commercial swimming pools and spas.
  • Page 9: General Warnings

    Pentair Water Pool and Spa ® PUMP WARNING AND SAFETY INSTRUCTIONS For Pool and Spa Pumps (Non SVRS Pumps) (Pentair Water Pool and Spa , Sta-Rite , and Pentair Pool Products ® ® ® General Installation Information • All work must be performed by a qualified pool professional, and must conform to all national, state, and local codes.
  • Page 10: Save These Instructions

    Pentair Water Pool and Spa ® PUMP WARNING AND SAFETY INSTRUCTIONS For Pool and Spa Pumps (Non SVRS Pumps) (Pentair Water Pool and Spa , Sta-Rite , and Pentair Pool Products ® ® ® General Warnings, (Continued). • Never open the inside of the drive motor enclosure. There is a capacitor bank that holds a 230 VAC charge even when there is no power to the unit.
  • Page 11: Section 1: Introduction

    Thick walled body parts, a heavy duty 56 square flange motor, and highly engineered hydraulics make this rugged and tested design perfect for any pool, spa, water feature, or fountain. And SuperMax’s silent running capability and small footprint allow it to easily drop into a compact equipment pad.
  • Page 12: General Features

    • 1/2 Hp to 2 1/2 Hp configurations to accommodate a wide range of applications • Self-priming for quick, easy start-up • Every SuperMax pump is performance and pressure tested prior to shipment to ensure superior quality ® • UL/CUL/NSF SuperMax Pump Installation and User’s Guide...
  • Page 13: Section 2: Electrical Requirements

    Section 2 Electrical Requirements This section describes how to wire the SuperMax pump. ® Note: Before installing this product, read and follow all warning notices and instructions on pages ii-vi. Electrical Requirements and Wiring WARNING — Risk of electrical shock or electrocution.
  • Page 14 GFCI circuit breaker, use a dedicated circuit breaker that has no other electrical loads. 10. Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same circuit. Ground Screw Figure 1. SuperMax Pump Installation and User’s Guide ®...
  • Page 15: Section 3: Maintenance

    Section 3 Maintenance This section describes how to maintain the SuperMax pump. ® The Pump Strainer Basket This unit, sometimes referred to as the ‘Hair and Lint Pot’, is the unit in front of the volute. Inside the chamber is the basket which must be kept clean of leaves and debris at all times. View basket through the ‘See Through Lid’...
  • Page 16 13. Stand clear of the filter. Start the pump. 14. Bleed air from the filter until a steady stream of water comes out. Close the manual air relief valve. CLAMP O-RING BASKET VOLUTE CLAMP VOLUTE Figure 4. Figure 3. SuperMax Pump Installation and User’s Guide ®...
  • Page 17: Winterizing

    • DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, for winter storage, etc., but never when operating, or expecting operation. • When replacing the motor, be certain that the motor support is correctly positioned to support the size of motor being installed. SuperMax Pump Installation and User’s Guide ®...
  • Page 18: Section 4: Servicing

    Section 4 Servicing This section describes how to service the SuperMax pump. ® WARNING — Risk of electrical shock or electrocution. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
  • Page 19: Pump Reassembly/Seal Replacement

    2. The pump requires little or no service other than reasonable care, however, a Shaft Seal may occasionally become damaged and must be replaced. BOLT SEAL PLATE IMPELLER LOCKING SCREW MOTOR SLINGER MOTOR SHAFT SEAL PLATE O-RING QUAD IMPELLER DIFFUSER RING SCREW Figure 5. SuperMax Pump Installation and User’s Guide ®...
  • Page 20: Section 5: Restart Instructions

    Section 5 Restart Instructions If the SuperMax pump is installed below the water level of the pool, close return and suction lines prior to ® opening hair and lint pot on pump. Make sure to reopen valves prior to operating.
  • Page 21: Section 6: Troubleshooting

    Section 6 Troubleshooting Use the following troubleshooting information to resolve possible problems with your SuperMax pump. ® WARNING — risk OF elecTrical shOck Or elecTrOcuTiON. Improperly installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
  • Page 22: Section 7: Technical Data

    Illustrated Parts List 22 20 Item Part Description Item Part Description single SPEED SUPERMAx MOTORS 355621 SCREW ¾-16 X 2¼ HEX HD, 4 req. ½, ¾ HP — (Black) 355019S 072184 WASHER 3/8 in. S/S, 4 req. 355021S 1 HP — (Black)
  • Page 23: Pump Curve

    Pump Curve Pentair Water Pool and Spa, Inc. Pump Performance Curve ® Pentair Water Pool and Spa, Inc. SuperMax Series Pump Performance Curve SuperMax ®Series 3450 RPM 2 HP 2 ½ HP 1750 RPM 1 ½HP 1 HP ½, ¾ HP 1 HP 1 ½...
  • Page 24 NOTES SuperMax Pump Installation and User’s Guide ®...
  • Page 25 SAVE THESE INSTRUCTIONS...
  • Page 26 *354708* LIT PKG. P/N 354708 *351096* P/N 351096 Rev. F 2/22/12...

Table of Contents