lan2de.c01
Introduction

Short description

Interfaces:
10/100MB Autosense Ethernet twisted-pair,
Up to 16 B channels,
SLIP access (serial line interface) for initial startup, incl. cable (reference no.
S30122-X5468-X).

1.1.1 Prerequisite

For this application, TCP/IP is implemented as the transport protocol and Win95/98
or Win NT 4.0 as the client operating system. For the routing functionality, the IP/IPX
protocols are transferred transparently, independent of the operating system. Call
numbers are allocated in HiPath HG 1500 via TCP/IP Address > Call Number (max.
100 call numbers for vCAPI and max. 48 stations for voice applications). The
assignment of several call numbers to one TCP/IP address may be necessary if
several services are to be configured (voice, fax, file transfer, etc.).
1.2 Short description
HiPath HG 1500 is an expansion card for Hicom 150 E Office/Hicom 150 H Point/
Com/Pro. It is used to connect a "local" LAN to Hicom 150 E Office/ Hicom 150 H
Point/Com/Pro systems and to link "external" LANs via the system's ISDN interface.
Telematics and CTI functions are also supported.
The connection to the "local" LAN is set up via an Ethernet twisted-pair interface
(RJ45 connector); see Figure 2-1 and Figure 2-2.
In the case of OfficePoint and Com, the connection to the system is set up via a 50-
pin edge connector of an expansion slot. The connection to the LAN is set up via an
RJ45 connector on the Hicom Xpress @LAN board.
In the case of OfficePro, the board is connected to the system via the backplane. The
LAN connection is set up using an RJ45 connector via an adapter (part number
C39228-A7195-A10) for the backplane.
V.24 interface
For loading and administration purposes (SLIP access), each system is provided with
an individual V.24 interface (cable reference no. S30122-X5468-X). In both systems,
the V.24 connector for SLIP access is located on the board.

1.3 Service information

The unique worldwide Ethernet address (MAC address) is a factory default and
cannot be modified.