3.2.1 Configuring HiPath HG 1500 (HLB2)

Step
1.
Under Voice Clients -> Gatekeeper:
Enter the IP address of the PC with the gatekeeper,
enable gatekeeper support and configure the prefix.
2.
Under Voice Clients -> H.323 Clients:
Configure the clients with a gatekeeper connection using IP address
"255.255.255.255".
Clients without a gatekeeper connection must be configured with the fixed
IP address of the corresponding PC.
3.
Under Voice Clients -> Xpress Clients:
There are no additional aspects to be noted here.

3.2.2 Configuring the NGK 100 gatekeeper

Relevant options under "Settings"
Step
1.
Capacity Characteristics:
Set the IRQ interval to 0 if the registered endpoints do not need to be cy-
clically polled, e.g. when using RAS connections for teleworking.
2.
Call and Registration Policy:
Accept Call must be enabled.
Set All Endpoints or Predefined endpoints.
3.
Routing Mode:
Set Gatekeeper Routed or Direct Routed.
A31003-K5020-S100-4-7620
Service Manual
Configuration for gatekeeper mode