Scene Commands; Hdcp Compliance; Edid Configuration - KanexPro HDMX44-18G User Manual

4k 4x4 hdmi 2.0 matrix switcher
Hide thumbs Also See for HDMX44-18G:
Table of Contents

Advertisement

KANEXPRO
%9976.

6.3.4 Scene Commands

Command
Save[Y].
Recall[Y].
Clear[Y].

6.3.5 HDCP Compliance

Command
/%[Y]/[X]:[Z].
%0801.
%9973.
%9974.

6.3.6 EDID Configuration

The DIP switcher status should be set as 1111 to enable Software EDID management
mode: RS232 control or Web-based GUI control.
Command
16 |
P a g e
Query the output resolution.
Function
Save the present operation to the
preset command [Y], ranges from 1 to
10.
Recall the preset command [Y].
Clear the preset command [Y].
Function
HDCP management command.
Y=O is for output;
X=1~4 is the number of the port, if the
X=ALL, it means all ports;
Z is for HDCP compliant status, the
value may be 1 (HDCP compliant) or
0 (not HDCP compliant).
Auto HDCP management, activate
carrier native mode
Query the HDCP status of the input
signals.
Query the HDCP status of the output
signals.
Function
HDMX44-18G
Resolution
Out 1 1920x1080P
Out 2 1920x1080P
Out 3 1920x1080P
Out 4 1920x1080P
Feedback Example
Save To FY (Y=1-10)
Recall From FY (Y=1-
10)
Clear FY
(Y=1-10)
Feedback Example
/%O/ALL:0.
%0801
In 01 02 03 04
HDCP Y N Y N
Out 01 02 03 04
HDCP Y N Y N
Feedback Example