ABB REG670 Technical Manual page 73

Relion 670 series 2.0 iec generator protection
Hide thumbs Also See for REG670:
Table of Contents

Advertisement

1MRK502052-UEN B
Name
Values (Range)
CTStarPoint4
CTsec4
CTprim4
CTStarPoint5
CTsec5
CTprim5
CTStarPoint6
CTsec6
CTprim6
CTStarPoint7
CTsec7
CTprim7
CTStarPoint8
CTsec8
CTprim8
CTStarPoint9
CTsec9
CTprim9
CTStarPoint10
CTsec10
CTprim10
CTStarPoint11
CTsec11
CTprim11
CTStarPoint12
CTsec12
CTprim12
Table 10:
TRM_6I_6U Non group settings (basic)
Name
Values (Range)
CTStarPoint1
CTsec1
CTprim1
Table continues on next page
Technical manual
Unit
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
Unit
FromObject
-
ToObject
1 - 10
A
1 - 99999
A
Step
Default
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
-
ToObject
1
1
1
3000
Step
Default
-
ToObject
1
1
1
3000
Section 3
Analog inputs
Description
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
Description
ToObject= towards protected object,
FromObject= the opposite
Rated CT secondary current
Rated CT primary current
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents