Communication Connectors - SolarEdge storedge Installation Manual

Hide thumbs Also See for storedge:
Table of Contents

Advertisement

Communication Connectors

Two communication glands are used for connection of the various communication options. Each gland 
has three openings. The table below describes the functionality of each opening.   U nused openings should 
remain sealed.
Gland#
Opening
One small
1 (PG16)
Two large
2 (PG13.5)
All three
The communication board has a standard RJ45 terminal block for Ethernet connection, and a 9-pin 
terminal block for RS485 connection,   a s shown below:
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.2
Chapter 8: Setting Up Communication to the Monitoring Platform
Functionality
External antenna cable
Ethernet connection (CAT5/6),
ZigBee, Cellular
RS485, power reduction
Figure 31: Communication Glands
Figure 32: Internal connectors
Cable Size (diameter)
2-4 mm
4.5-7 mm
2.5-5 mm
71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents