Levels. If the user attempts to save a procedure to
memory location that is locked, the Mode Select Panel
will briefly display "Memory Save is DISABLED!".
Presently, Memory Panel Lockout Levels can only be
accessed through Weld Manager.
Saving a Procedure to a Memory
Location
Once the parameters have been set:
Press and Hold the Memory button of the
desired location for 2 seconds.
The LED for that location will come ON.
After 2 seconds the LED will go OFF
The MSP display will show briefly that the
information is saved, then return to the Weld
Mode.
NOTE: Do not hold the button for longer than 5 seconds.
Recalling a Procedure from a Memory
Location
Press and release the desired Memory Button.
The LED for that location will come ON and the
stored procedure information will show in the
displays.
The LED will remain ON until another location is
selected
NOTE: Do not hold the button for longer than 1 second
1.
MSP DISPLAY
2.
LED INDICATOR
3.
MEMORY BUTTON
Hold for 2 seconds to save
Press and release to recall
Optional Limit Setup
The Limits feature allows the operator to set minimum
and maximum values for various parameters depending
on the Weld Mode selected.
Each memory location may have a different set of limits,
even if the Weld Mode is the same. For example:
Memory Location 1 can be set for a maximum wire feed
speed of 140"/min; Memory Location 2 may be set for a
minimum of 100"/min and a maximum of 160"/min and
Memory Location 3 may have no WFS limit set.
English
Parameters are constrained by the machine limitations
or by memory limits. When the Memory Limits are
enabled the parameter will flash if an attempt is made to
set a value outside of the prescribed limit (if less than the
machine capabilities). The parameter will not flash if an
attempt is made to exceed the machine limits.
NOTE: Weld Modes cannot be selected through the
Limits Setup Menu. They must be chosen and saved
before entering the Limits Menu.
Setting Limits
1.
Press and hold the desired Memory Button until the
LED for that location begins to blink rapidly.
The MSP Display will read:
2.
After 2 seconds the display will change to show the
following items:
Memory Value
1.
Set High Limit
2.
Value Low Limit
3.
Set Low Limit
4.
Parameter Name
3.
The Parameter Name on the MSP Display will flash
to indicate it is ready to be changed. If no limits
were previously set, the High and Low values are
the limits of the Power Source
Press the Arc Start/End Options button to select
that parameter.
Use the Mode Select Panel Control to adjust
the High Limit (flashing).
Press the Arc Start/End Options button.
Use the the Mode Select Panel Control to
adjust the Value (flashing).
Press the Arc Start/End Options button.
Use the the Mode Select Panel Control to
22
High Limit
Low Limit