Lincoln Electric MAXsa 10 Operator's Manual page 22

Hide thumbs Also See for MAXsa 10:
Table of Contents

Advertisement

P.23
Trigger Fan-Out
For Sub-Arc Lead Arc machines only. Allows the Lead Arc MAXSA™ 10 to control all machine triggers in a
multi-arc system.
No = Only the machine connected to the MAXSA™10 can be triggered on and off (default).
Yes = All machines in the system can be triggered on and off simultaneously.
P.30
Input Control
This option allows the front panel controls of the MAXSA™ 10 to be enabled/disabled. The remote
inputs are always functional when connected, but there may be applications where it is neces- sary to
disable the inputs on the pendent. Panel & Remote = All pendent buttons are enabled (default). Panel
Locked = The Start, Flux and feed buttons are disabled at the pendent. The pendent's Stop button is
always active and cannot be disabled
P.80
Sense From Studs
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
reset to False.
False = Voltage sensing is automatically determined by the selected weld mode and other machine settings
(default).
True = Voltage sensing is forced to "studs".
P.99
Show Test Modes?
Most power sources contain weld modes used for calibration and test purposes. By default, the
machine does not include test weld modes in the list of weld modes that are available to the operator. To
manually select a test weld mode, set this option to "Yes". When the power source is turned off and back
on again, the test modes will no longer appear in the mode list. Test weld modes typically require the
machine output to be connected to a grid load and cannot be used for welding.
P.100
View Diagnostics?
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes" to access
the diagnostic options in the menu. Additional parameters will now appear in the setup menu (P.101, P.102,
etc).
P.101
View Event Logs
Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate Control Knob
to select the desired event log to read. Press the Right Button again to enter the selected log. Rotating the
Control Knob will scroll through the event log, displaying the log index number, event code and some other
data. Press the Left Button to back out to select another log. Press the Left Button again to exit this option.
P.102
View Fatal Logs
Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate Control Knob
to select the desired fatal log to read. Press the Right Button again to enter that log. Rotating the Control
Knob will scroll through the log, displaying the log index number and fatal code. Press the Left Button to
back out to select another log. Press the Left Button again to exit this option.
P.103
View Software Version Information
Used for viewing the software versions for each board in the system. Press the Right Button to enter the
option. Rotate Control Knob to select the desired board to read. Press the Right Button again to read the
firmware version. Press the Left Button to back out to select another board. Rotate the Control Knob to
select another board, or press the Left Button to exit this option.
P.104
View Hardware Version Information
Used for viewing the hardware version for each board in the system. Press the Right Button to enter the
option. Rotate Control Knob to select the desired board to read. Press the Right Button again to read the
hardware version. Press the Left Button to back out to select another board. Press the Left Button again to
exit this option.
P.105
View Welding Software Information
Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld Set version.
Press the Left Button to back out and exit this option.
P.106
View Ethernet IP Address
Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to read the IP
Address. Press the Left Button to back out and exit this option. The IP address can- not be changed using
this option.
P.107
View Power Source Protocol
Used for viewing the type of power source the feeder is connected to. Press the Right Button to identify the
power source as either LincNet or ArcLink. Press the Left Button to back out and exit this option.
P.501
Encoder Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire feed speed,
amps, volts or trim. The function of each upper knob depends on the selected weld mode. When a constant
current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right knob will always function as an
on/off switch. This parameter can only be accessed using Power Wave Manager software.
P.502
Memory Change Lockout
Determines if the memories can be overwritten with new contents.
No = Memories can be saved and limits can be configured (default).
Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.
This parameter can only be accessed using Power Wave Manager software.
P.503
Memory Button Disable
Disables the specified memory button(s). When a memory is disabled, welding procedures can- not be
English
19
English