10 Supplement
Antenna encapsulation
PTFE
PFA and PFA 8 mm
Vibration resistance
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
10)
Ʋ Single chamber housing
Ʋ Double chamber housing
Spring-loaded terminals for wire cross-
section
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Ʋ Single chamber housing
Ʋ Double chamber housing
Connection cable
Ʋ Wire cross-section
Ʋ Wire resistance
Tested according to the guidelines of German Lloyd, GL directive 2.
9)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/8" FF.
10)
54
Version
Additional process seal,
FKM
Additional process seal,
EPDM
Standard
mechanical vibrations with 4 g and 5 ... 100 Hz
– 1 x cable gland M20 x 1.5 (cable: ø 5 ... 9 mm), 1 x
blind plug M20 x 1.5
or:
– 1 x closing cap M20 x 1.5; 1 x blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
– 1 x plug (depending on the version), 1 x blind stopper
M20 x 1.5
– 1 x cable entry M20 x 1.5 (cable: ø 5 ... 9 mm), 1 x
blind plug M20 x 1.5; 1 x blind plug M16 x 1.5 or
optionally available with 1 x plug M12 x 1 for external
display and adjustment unit
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, 1 x blind
plug M16 x 1.5 or optionally 1 x plug M12 x 1 for exter-
nal display and adjustment unit
or:
– 1 x plug (depending on the version), 1 x blind plug
M20 x 1.5; 1 x blind plug M16 x 1.5 or optionally avail-
able with 1 x plug M12 x 1 for external display and
adjustment unit
< 2.5 mm² (AWG 14)
1 x IP 68 cable gland M20 x 1.5; 1 x blind plug M20 x 1.5
1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M20 x 1.5; 1 x blind stopper M16 x 1.5
0.5 mm² (AWG 20)
< 0.036 Ω/m (0.011 Ω/ft)
Process temperature (measured on the process
fitting)
-20 ... +130 °C (-4 ... +266 °F)
-40 ... +130 °C (-40 ... +266 °F)
-40 ... +150 °C (14 ... +302 °F)
VEGAPULS 63 • Foundation Fieldbus