Siemens SITRANS P DS III Operating Instructions Manual page 221

Digital pressure transmitter
Hide thumbs Also See for SITRANS P DS III:
Table of Contents

Advertisement

Construction of pressure transmitter with PMC connection
Electrical connection
Degree of protection for Han and
M12 connectors
Han 8D is identical to Han 8U.
1)
Design for absolute pressure (from the differential pressure series), differential pressure and flow rate
Weight
Material
Wetted parts materials
Seal diaphragm
Pressure caps and locking screw Stainless steel, mat. no. 1.4408 to PN 160, mat. no. 1.4571/316Ti for PN 420,
O-ring
Non-wetted parts materials
Electronics housing
Pressure cap screws
Mounting bracket
Measuring cell filling
Process connection
SITRANS P DS III/P410 with PROFIBUS PA
Operating Instructions, 02/2016, A5E00053276-08
Cable inlet using the following cable glands:
Pg 13.5
M20 x 1.5
½-14 NPT
Han 7D/Han 8D plug
1)
M12 connector
IP65
Approx. 4.5 kg (9.9 lb) for aluminum enclosure
Stainless steel, mat. no. 1.4404/316L, Hastelloy C276, mat. no. 2.4819, Monel,
mat. no. 2.4360, tantalum or gold
Hastelloy C4, 2.4610 or Monel, mat. no. 2.4360
FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR
Non-copper aluminum die casting GD-AlSi 12 or stainless steel precision cast-
ing, mat. no. 1.4408
Standard: Powder coating with polyurethane
Option: 2 coats: Coat 1: epoxy-based; coat 2: polyurethane
Stainless steel nameplate
Stainless steel
Steel or stainless steel
Silicone oil
Neobee M20
Inert liquid
(max. 120 bar g (2320 psi g) for oxygen measurement)
/
-18 NPT female thread and flat connection with
1
4
thread in accordance with EN 61518 or M10 fastening screw thread in accordance
with DIN 19213 (M12 for PN 420 (MAWP 6092 psi))
Technical data
13.8 Construction
/
-20 UNF fastening screw
7
16
221

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans p410

Table of Contents