Check code
HIC piping temperature thermistor (TH2) open/short
5109
Abnormal points and detection methods
Abnormal if TH2 detects to be open/short.
Open: -40 [-40°F] or less
Short: 90 [194°F] or more
●Diagnosis of defectives
Make sure to turn the power OFF before connecting/disconnecting
any connectors, or replacing boards.
Check the wiring and connector connection of TH2.
Is there any abnormality such
as a disconnection, looseness or
breakage?
Disconnect the connector to check the
resistance of TH2 using a tester.
Is the detected resistance normal?
Check a temperature of TH2.
Is the detected temperature normal?
OCH502C
TH2: HIC piping temperature thermistor
Diagnosis
Yes
No
No
Yes
No
Yes
Causes and check points
Disconnection or contact failure of connectors
Characteristic defect of thermistor
Defective outdoor controller board
The black square (■) indicates a switch position.
Connect the wiring/connector properly.
Replace it in case of a breakage.
Replace the thermistor.
The detected temperature of TH2 can be displayed by
an operation of SW1 on the outdoor controller board.
SW1 Setting
Display on LED1,2
Unit
ON
-99.9
999.9
°C
OFF
1 2 3 4 5 6 7 8
*F=(9/5)×°C+32
Replace the controller board
(Malfunction of thermistor circuit).
No abnormality
( A connector contact failure is suspected).
62
Remedy