SPECIFICATIONS

3
Item
Cooling Capacity
Heating Capacity
***
Input ( Cool )
Input Current ( Cool )
***
Power factor (Cool)
***
Input ( Heat )
***
***
Input Current ( Heat )
Power factor (Heat)
***
EER ( Cool )
***
***
COP ( Heat )
Connectable indoor units ( Max. )
Max. Connectable Capacity
Power Supply
Breaker Size
Max. fuse size
Min.Circuit.Ampacity
Sound level ( Cool/Heat )
External finish
Refrigerant control
Compressor
Model
Motor output
Capacity control
Starting method
Crankcase heater
Heat exchanger
Fan ( drive ) o No.
Fan
Fan motor output
Airflow
Dimensions ( H o W o D )
Weight
Refrigerant
Charge
Oil ( Model )
Protection
High pressure protection
devices
Compressor protection
Fan motor protection
Total Piping length ( Max. )
Farthest
Max Height difference
Chargeless length
Liquid
Piping diameter
Guaranteed operation range
Rating conditions
Cooling
Indoor : D.B. 26.7°C / W.B. 19.4°C
[D.B. 80°F / W.B. 67°F]
Outdoor : D.B. 35°C [D.B. 95°F]
Heating
Indoor : D.B. 21.1°C [D.B. 70°F]
Outdoor : D.B. 8.3°C / W.B. 6.1°C
[D.B. 47°F / W.B. 43°F]
OCH502C
Service Ref.
Btu/h
Btu/h
kW
A
%
kW
A
%
Btu/h/W
W/W
Btu/h
dB
kW
%
W
kW
/min [ CFM]
m
3
mm [ in ]
W
mm [ in ]
D
mm [ in ]
H
kg [ lb ]
kg [ lb ]
L [oz]
m [ft]
m [ft]
m [ft]
m [ft]
[mm[in]
[mm[in]
Gas
( cool )
( heat )
*40m [140ft] : In the case of installing outdoor unit lower than indoor unit.
**10 - 46°C [50 - 115°F]DB : In the case of connecting PKFY-P06/P08 type
indoor unit.
***Electrical data is for only outdoor unit.
(In case of connecting 4 indoor units of PKFY-P06NBMU×2 and PKFY-
P24NKMU×2)
Btu/h=kW × 3,412
Note: Above specification data is subject to rounding variation.
PUMY-P60NKMU(-BS)
60,000
66,000
4.80
21.5
97.0
6.15
27.6
97.0
12.5
3.14
12
78,000 ( 130% )
Single phase , 60Hz , 208/230V
40A
42A
25A
58 / 59
Munsell 3Y 7.8/1.1
Linear Expansion Valve
Hermetic
ANB66FFZMT
3.0
Cooling 38-100
Heating 29-100
Inverter
Plate fin coil ( Anti corrosion fin treatment )
Propeller fan o 2
0.16 + 0.16
140 [4,940]
1,050 [ 41-5/16]
330+30 [ 13+1-3/16 )
1 , 338 [ 52+11/16 ]
142 [313]
R410A
5.1 [ 11.2 ]
2.3 [73] ( FV50S )
HP switch
Compressor thermo,
Over current detection
Overheating/Voltage protection
150 [492]
80 [262]
50 [164] *
0 [0]
9.52 [ 3/8 ]
19.05 [ 3/4 ]
: DB [23 - 115 ° F DB]**
:
° F WB]
CFM=K/min × 35.31
10
lbs=kg/ 0.4536