Mitsubishi PUMY-P60NKMU Technical & Service Manual page 41

Split-type, heat pump air conditioners
Table of Contents

Advertisement

Check code
1302
●Diagnosis of defectives
Make sure to turn the power OFF before connecting/disconnecting any connectors, or replacing boards.
Continued from the previous page
Is there a resistance detected?
Disconnect the indoor LEV wiring to check
the resistance.
Is there a resistace detected?
Check the voltage and appearance of the
indoor controller board.
Is the voltage normal?
Is it free from any trace of over-
heating or burning?
Check the resistance of SV1.
Continue to the next page
OCH502C
High pressure trouble
Diagnosis
No
Yes
No
Yes
Yes
Replace the indoor LEV.
No
Replace the indoor controller board.
41
Chart 3 of 4
Remedy
Replace the TH7.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pumy-p60nkmu-bs