Countermeasures For Error During Test Run - Mitsubishi PUMY-P60NKMU Technical & Service Manual

Split-type, heat pump air conditioners
Table of Contents

Advertisement

8-1-3. Countermeasures for Error During Test Run

• If a problem occurs during test run, a code number will appear in the temperature display area on the remote controller (or
LED on the outdoor unit), and the air conditioning system will automatically cease operating.
Determine the nature of the abnormality and apply corrective measures.
Note that this document describes flow charts for solving trouble/error(s) which is detected in outdoor unit only.
Check
code
0403
Serial communication error
1102
Compressor temperature
1300
Low pressure
1302
High pressure
1500
Superheat due to low discharge temperature
Insuffi cient refrigerant trouble
1501
Blocked valve in cooling mode
1508
4-way valve trouble in heating mode
2500
Water leakage
2502
Drain pump trouble
2503
Drain sensor trouble (THd)
4100
Compressor current interruption( locked compressor)
4210
Compressor over current interruption
Voltage shortage/overvoltage/PAM error/T-open phase/power syncronization
4220
signal error
4230
Heatsink temperature
4250
Power module
4400
Rotational frequency of outdoor fan motor
Air inlet sensor trouble (TH21) or
5101
Compressor temperature thermistor (TH4) open/short
Liquid pipe temp.sensor trouble (TH22) or
5102
Low pressure saturated temp.thermistor (TH6) open/short
5103
Gas pipe temperature sensor trouble (TH23)
5105
Piping temperature thermistor (TH3) open/short
5106
Piping temperature thermistor (TH7) open/short
5109
HIC piping temperature thermistor (TH2) open/short
5110
Heatsink temperature sensor thermistor (TH8) open/short
5201
High pressure sensor (63HS)
5202
Low pressure sensor (63LS)
5300
Primary current
5701
Contact failure of drain fl owt switch
6600
Duplex address error
6602
Transmission processor hardware error
6603
Transmission bus BUSY error
6606
Signal comminication error with transmission processor
6607
No ACK error
6608
No responce frame error
6831
MA communication receive signal error (no receive signal)
6832
MA commnication send signal error (starting bit derection error)
6833
MA commnication send error (H/W error)
6834
MA commnication receive error (Synchronous recovery error)
7100
Total capacity error
7101
Capacity code error
7102
Connecting excessive number of units
Address setting error
7105
Remote controller sensor trouble
7111
Note:
When the outdoor unit detects No ACK error/No response error, an object indoor unit is treated as a stop, and not assumed to be abnormal.
Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch
(SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
During normal operation
The LED indicates the drive state of the controller in the outdoor unit.
Bit
1
2
Compressor
Indication
52C
operated
OCH502C
Trouble
3
4
5
21S4
SV1
(SV2)
Detected Unit
Remote
Indoor Outdoor
Controller
Outdoor unit Multi controller board ~
Power board communiation trouble
Check delay code 1202
Check delay code 1402
Check delay code 1600
Check delay code 1601
Check delay code 1501
Check delay code 1608
Check delay code 4350
Check delay code 4320
Check delay code 4330
Check delay code 4350
Check delay code 4500
Check delay code 1202
Check delay code 1211
Check delay code 1205
Check delay code 1221
Check delay code 1222
Check delay code 1214
Check delay code 1402
Check delay code 1400
Check delay code 4310
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected.
Only M-NET Remote controller is detected. *
Only M-NET Remote controller is detected. *
Only MA Remote controller is detected.
Only MA Remote controller is detected.
Only MA Remote controller is detected.
Only MA Remote controller is detected.
6
7
8
Always lit
32
Remarks
[Example]
When the compressor and
SV1 are turned during cooling
operation.
1 2 3 4 5 6 7 8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pumy-p60nkmu-bs

Table of Contents