Wiring Diagram - Mitsubishi PUMY-P60NKMU Technical & Service Manual

Split-type, heat pump air conditioners
Table of Contents

Advertisement

WIRING DIAGRAM

6
PUMY-P60NKMU
PUMY-P60NKMU-BS
OCH502C
63LS
63HS
MULTI.B.
1
7
CNF1
1
3
MF1
(WHT)
63HS
MS
(WHT)
~
3
CNF2
1
3
MF2
(WHT)
1
7
63LS
MS
(BLU)
~
3
3
TRANS
1
2
CNDC
(PNK)
52C
21S4
SV2
SV1
3
(BLK) 1
3
(GRN)
3
(BLU)
2
(WHT)
1
1
21S4
SV1
2
1 2
CN4
(WHT)
TB3
2
RED
M1
M2
RED
S
WHT
TO INDOOR UNIT
CONNECTING WIRES
CB
DC 30V(Non-polar)
TB7
RED
YLW
2
M1
M2
YLW
S
FOR CENTRALIZED
CONTROL
DC 30V(Non-polar)
W V U
V
W
U
MS
3~
TB1
MC
RED
L1
POWER SUPPLY
BLU
~
/N
L2
AC208/230V 60Hz
GRN/YLW
GR
SYMBOL
NAME
TB1
Terminal Block <Power Supply>
TB3
Terminal Block <Comunication Line>
TB7
Terminal Block <Centralized Control Line>
MC
Motor For Compressor
MF1,MF2
Fan Motor
21S4
Solenoid Valve <Four-Way Valve>
63H
High Pressure Switch
63HS
High Pressure Sensor
63LS
Low Pressure Sensor
SV1
Solenoid Valve <Bypass Valve>
TH2
Thermistor <HIC Pipe>
TH3
Thermistor <Outdoor Pipe>
TH4
Thermistor <Compressor>
TH6
Thermistor <Low Pressure Saturated>
TH7
Thermistor <Outdoor>
TH8
Thermistor <Heat Sink>
LEV-A,LEV-B Electronic Expansion Valve
Cautions when servicing
WARNING: When the main supply is turned off, the voltage [340 V] in the main capacitor will drop to 20 V in approx. 2
!
minutes (input voltage: 230 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then
wait for at least 1 minute.
• Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual.
Do not replace the outdoor board without checking.
NOTES:
1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit.
Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch
(SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
• During normal operation
• The LED indicates the drive state of the controller in the outdoor unit.
Bit
1
2
3
Compressor
Indication
52C
21S4
operated
• When fault requiring inspection has occurred
The LED alternately indicates the inspection code and the location of the unit in which
the fault has occurred.
LEV-A
TH7 TH6 TH3 TH4 TH2
63H
M
CN3D
CN3S
CN3N
1
4
1 2 1 2 1 2
(WHT)
(RED)
(BLU)
TH7/6
TH3
TH4
TH2
1
(RED)
(WHT)
(WHT)
(BLK)
1
3 1
3 1
3
CNLVA
(WHT)
63H
(YLW)
1
3
CN52C
(RED)
CN2
1
3
(WHT)
7
1
CN4
(WHT)
3
1 2
7
2
F1
CNS1
CNS2
LED3
F2
SS
(RED)
(YLW)
3
2
1
1
(WHT)
1
2
1
CNAC
(RED)
2
2
7
3
1
7
1
CN2
(WHT)
52C
52C
2
CNDC
N2
(PNK)
3
1
P2
IGBT
TH8
DCL2
DCL1
E I
DCL
SYMBOL
NAME
DCL
Reactor
CB
Main Smoothing Capacitor
P.B.
Power Circuit Board
TABU/V/W
Connection Terminal <U/V/W-Phase>
TABLI/NI
Connection Terminal <L/N-Phase>
TABP2
Connection Terminal <DC Voltage>
TABN2
Connection Terminal <DC Voltage>
DCL1,DCL2
Connection Terminal <Reactor>
IGBT
Power Module
EI,E2,E3,E4
Connection Terminal <Ground>
MULTI.B.
Controller Circuit Board
SW1
Switch <Display Selection>
SW2
Switch <Function Selection>
SW3
Switch <Test Run>
SW4
Switch <Model Selection>
SW5
Switch <Function Selection>
SW6
Switch <Function Selection>
4
5
6
7
Always lit
SV1
(SV2)
18
LEV-B
M
The black square ( ) indicates
a switch position.
SWU2 SWU1
SW5
SW6
6
1
6
CNLVB
SW1
?SW8
SW2
(RED)
*
1
5
SW4
SW3
SW7
CN51
(WHT)
LED1
LED2
CN102
(WHT)
4
1
CN41
CN40
(WHT)
(WHT)
2 1
4
1 4
1
4
2
M-P.B.
1
4
CN2
TP1
(WHT)
(BLK)
CN1
(WHT)
5
3
1
2
P. B.
CN52C
(RED)
3
BLK
E3
1
2
3
E2
BLK
2
1
3
E4
N I
L I
* MODEL SELECT 1:ON 0:OFF
SW4
SW8
MODEL
1 2 3 4 5 6 1
2
PUMY-P60NKMU(-BS)
0 1 1 0 0 0 0
0
SYMBOL
NAME
SW7
Switch <Function Selection>
SW8
Switch <Model Selection>
SWU1
Switch <Unit Address Selection, 1st digit>
SWU2
Switch <Unit Address Selection, 2nd digit>
SS
Connector <Connection For Option>
CN3D
Connector <Connection For Option>
CN3S
Connector <Connection For Option>
CN3N
Connector <Connection For Option>
CN51
Connector <Connection For Option>
LED <Operation Inspection Display>
LED1,LED2
LED3
LED <Power Supply to Main Microcomputer>
F1,F2
Fuse <T6. 3AL250V>
X501
~
505
Relay
M-P.B.
M-NET Power Circuit Board
TP1
ConnectionTerminal <Ground>
[Example]
When the compressor and
SV1 are turned during cooling
operation.
8
1 2 3 4 5 6 7 8