Fan Population Guidelines; Installing A Hot-Swap Fan Module - HP ProLiant DL60 Gen9 User Manual

Hide thumbs Also See for ProLiant DL60 Gen9:
Table of Contents

Advertisement

Fan population guidelines

Configuration
One processor,
non-redundant
One processor,
redundant
Two processors,
non-redundant
Two processors,
redundant
In the redundant fan mode:
If one fan rotor fails, the system continues to operate without redundancy. This condition is
o
indicated by a flashing amber Health LED.
If two fan rotors fail, the operating system shuts down.
o

Installing a hot-swap fan module

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To install the component:
Power down the server (on page 15).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 15).
o
Remove the server from the rack (on page 18).
o
Remove the access panel (on page 18).
4.
Remove the air baffle (on page 19).
5.
Fan bay
Fan bay
Fan bay
1
2
3
Fan
Fan
Blank
Fan
Fan
Fan
Fan
Fan
Blank
Fan
Fan
Fan
Fan bay
Fan bay
Fan bay
4
5
6
Fan
Blank
Blank
Fan
Fan
Blank
Fan
Blank
Fan
Fan
Fan
Fan
Hardware options installation 47