The Gateway's Event Log can record and display as many as 6000 system events. Events are stored
locally in the Gateway, in chronological order and sent to your monitoring company as needed.
When the maximum number of stored events is reached, the oldest 2000 entries are deleted to
make room for logging new events.
The Event log, viewed from the MyHome Gateway App, provides a description of the event and an
event code. The tables below provide definitions of the events/codes that may be transmitted to
the Central Station and/or displayed by the MyHome Gateway App. ("E" Codes indicate an Event
and "R" codes indicate the event was Restored.)
NOTE: If the Gateway's backup battery is exhausted after AC power is lost, any system activity
occurring after Low Battery notification is not saved. Additionally, the Gateway reverts to the status
condition as before the low battery notification.
Event Code
110
Alarm, Fire
121
Alarm, Duress
122
Alarm, Silent
123
Alarm, Audible
131
Alarm, Perimeter
132
Alarm, Interior
134
Alarm, Entry/Exit
135
Alarm, Day/Night
137
Alarm, Tamper
145
Expansion Module Tamper
146
Silent Burglary
150
24-Hour Non-Burglary
162
Carbon Monoxide Detected
301
Trouble, AC Loss
302
Trouble, Low System Battery
305
Trouble, System Reset
308
System shutdown
316
System Tamper*
341
Trouble, Case Tamper
344
Trouble, RF Receiver Jam Detect
350
Long Range Radio Reset
353
Trouble, Long Range Radio Transmitter Fault
354
Failure to Communicate Event
373
Trouble, Fire Trouble
374
Trouble, Exit Error Alarm
380
Trouble, Sensor
381
Trouble, Loss of Supervision RF
383
Trouble, Sensor Tamper
Continued next page

Event Log Codes

Event Log Codes
Definition
52
Event Log Display
Fire
Duress
Silent
Audible
Perimeter
Interior
Entry/Exit
Day Night
Tamper
Expansion Module Tamper
Silent Burglary
24 Hour Non-Burglary
Carbon Monoxide Detected
AC Loss
Low system battery
System Reset
System shutdown
System Tamper
Cover Tamper
RF Jam Detect
Long Range Radio Reset
Comm. Trouble
Failure to Communicate Event
Fire trouble
Exit error alarm
Sensor trouble
Superv Loss-RF
Sensor Tamper