Troubleshooting - Hach CLF10sc User Manual

Reagentless chlorine analyzer
Hide thumbs Also See for CLF10sc:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Troubleshooting

Event log
The controller provides one event log for each sensor. The event log stores a variety of events that
occur on the devices such as calibrations done, calibration options changed, etc. A list of possible
events is shown below. The event log can be read out in a CSV format. For instructions on
downloading the logs, refer to the controller user manual.
Event
Power On
Flash Failure
1pointpHCalibration_Start
1pointpHCalibration_End
2pointpHCalibration_Start
2pointpHCalibration_End
1pointBufferpHCalibration_Start Start of one-point buffer calibration for pH
1pointBufferpHCalibration_End
2pointBufferpHCalibration_Start Start of two-point buffer calibration for pH
2pointBufferpHCalibration_End
TempCalibration_Start
TempCalibration_End
1pointChemZeroCL2_Start
1pointChemZeroCL2_End
1pointElecZeroCL2_Start
1pointElecZeroCL2_End
1pointProcessConc_Start
1pointProcessConc _End
2pointChemCL2_Start
2pointChemCL2_End
2pointElecCL2_Start
2pointElecCL2_End
CL2CalSetDefault
pHCalSetDefault
TempCalSetDefault
AllCalSetDefault
CL2CalOptionChanged
pHCalOptionChanged
TempCalOptionChanged
SensorConfChanged
16 English
Table 1 Event log
Description
The power was turned on.
The external flash has failed or is corrupted.
Start of one-point sample calibration for pH
End of one-point sample calibration for pH
Start of two-point sample calibration for pH
End of two-point sample calibration for pH
End of one-point buffer calibration for pH
End of two-point buffer calibration for pH
Start of temperature calibration
End of temperature calibration
Start of one-point chemical zero calibration for chlorine
End of one-point chemical zero calibration for chlorine
Start of one-point electrical zero calibration for chlorine
End of one-point electrical zero calibration for chlorine
Start of one-point process concentration for chlorine
End of one-point process concentration for chlorine
Start of two-point chemical calibration for chlorine
End of two-point chemical calibration for chlorine
Start of two-point electrical calibration for chlorine
End of two-point electrical calibration for chlorine
The chlorine calibration was reset to the default.
The pH calibration data was reset to the default.
The temperature calibration data was reset to the default.
All sensor calibration data was reset to the default.
The chlorine calibration option was changed.
The pH calibration option was changed.
The temperature calibration option was changed.
The sensor configuration was changed.