Adjusting The Remaining Bobbin Thread Level - ELNA 8300 Service Manual

Hide thumbs Also See for 8300:
Table of Contents

Advertisement

Model 8300

Adjusting the Remaining Bobbin Thread Level

Adjust the remaining bobbin thread level after replacing the circuit board A.
2
Main
Slave
DC1
Brightness
Foot UD
Card / USB
PH Sensor
Solenoid
Bobbin
5
1
3
Sensor Off
Aging
Solenoid Hold
BobbinCheck
4
6
1
Turn the power switch on while pressing the Start/Stop
button. Do not release the button until the LCD screen
shows the adjusting mode.
1 Power switch
2 Start/stop button
2
The LCD screen will show the adjusting mode.
3 Adjusting mode
3
Press the "Bobbin" key.
4
Wind a bobbin to 9.2 mm diameter and insert it into the
bobbin holder. Press the "Key" several times.
The same value will be shown in the box 4 under the
"Key" each time you press the key.
4 Box
5
Press the "MEM1" key and the value will be shown in
the box 5 under the "MEM1" and will be stored in the
memory.
5 Box
6
Wind another bobbin to 10.3 mm diameter and insert it
into the bobbin holder. Press the "Key" several times.
The same value will be shown in the box 4 under the
"Key" each time you press the key.
7
Press the "MEM2" key and the value will be shown in
the box
3
under the "MEM2" and will be stored in the
memory.
6 Box
8
Confirm it if the difference between the values MEM1
and MEM2 is not less than 6. If not, repeat the steps
from 4 to 7.
9
Press the "OK" key then turn the power switch off.
35