Default Values With Different Macros - ABB ACS310 User Manual

Hide thumbs Also See for ACS310:
Table of Contents

Advertisement

28 Actual values and parameters in the short view

Default values with different macros

When application macro is changed
the parameter values to their default values. The table below includes the parameter
default values for different macros. For other parameters, the default values are the
same for all macros. See the parameter list starting on page
chapter Actual signals and parameters in ACS310 User's Manual (3AUA0000044201
[English]).
Index Name/
ABB
Selection
ST ANDARD
9902
APPLIC
1 = ABB
MACRO
STANDARD
1001 EXT1
DI1,2
COMMANDS
1002 EXT2
NOT SEL NOT SEL NOT SEL NOT SEL DI5,4
COMMANDS
1003 DIRECTION
REQUEST REQUEST REQUEST REQUEST REQUEST FORWARD FORWARD FORWARD
1102 EXT1/EXT2
EXT1
SEL
1103 REF1
AI1
SELECT
1106 REF2
AI2
SELECT
1201 CONST
DI3,4
SPEED SEL
1304 MINIMUM AI2 0.0%
1401
RELAY
FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) PFC
OUTPUT 1
1601 RUN ENABLE NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL DI4
1805 DO SIGNAL
FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) FAULT(-1) PFC
2008
MAXIMUM
50.0 Hz
FREQ
2201 ACC/DEC 1/2
DI5
SEL
2202
ACCELER
5.0 s
TIME 1
2203
DECELER
5.0 s
TIME 1
3019 COMM FAULT
3.0 s
TIME
4001 GAIN
1.0
4002 INTEGRATION
60.0 s
TIME
4101 GAIN
1.0
4102 INTEGRATION
60.0 s
TIME
8116 AUX MOT
3.0 s
STOP D
8118 AUTOCHNG
NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL 0.1 h
INTERV
8123 PFC ENABLE NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL ACTIVE
(9902
APPLIC MACRO), the software updates
3-WIRE
ALTERNA
MOTOR
TE
POT
2 = 3-WIRE 3 = ALTER
4 = MOTOR
NATE
POT
DI1P,2P,3 DI1F,2R
DI1,2
EXT1
EXT1
EXT1
AI1
AI1
DI3U,
4D(NC)
AI2
AI2
AI2
DI4,5
DI3,4
DI5
0.0%
0.0%
0.0%
50.0 Hz
50.0 Hz
50.0 Hz
NOT SEL DI5
NOT SEL NOT SEL NOT SEL NOT SEL NOT SEL
5.0 s
5.0 s
5.0 s
5.0 s
5.0 s
5.0 s
3.0 s
3.0 s
3.0 s
1.0
1.0
1.0
60.0 s
60.0 s
60.0 s
1.0
1.0
1.0
60.0 s
60.0 s
60.0 s
3.0 s
3.0 s
3.0 s
29
in this manual and
HAND/
PID
PFC
AUTO
CONTROL
CONTROL
5 = HAND/
6 = PID
7 = PFC
AUTO
CONTROL
CONTROL
DI1,2
DI1
DI1
DI5
DI5
DI3
DI2
DI2
AI1
AI1
AI1
AI2
PID1OUT PID1OUT PID1OUT
NOT SEL DI3
NOT SEL NOT SEL
20.0%
20.0%
20.0%
NOT SEL NOT SEL
50.0 Hz
50.0 Hz
52.0 Hz
5.0 s
5.0 s
5.0 s
5.0 s
5.0 s
5.0 s
3.0 s
3.0 s
3.0 s
1.0
1.0
2.5
60.0 s
60.0 s
3.0 s
1.0
1.0
2.5
60.0 s
60.0 s
3.0 s
3.0 s
3.0 s
3.0 s
SPFC
CONTROL
15 = SPFC
CONTROL
DI1
DI5
DI2
AI1
20.0%
PFC
52.0 Hz
30.0 s
30.0 s
10.0 s
2.5
3.0 s
2.5
3.0 s
20.0 s
SPFC