Connecting a F3SJ-B to Four Muting Sensors

F39-JD A-L
Reflector
B1
Workpiece
A1
F3SJ-B
+24 VDC
Power
Supply
Unblocked
Blocked
A1 Safety output
B1 Safety output
B2 Safety output
A2 Safety output
Muting input 1
Muting input 2
Safety output
KM1, KM2, KM3, KM4 N.O. contact
KM1, KM2, KM3, KM4 N.C. contact
External indicator
F39-JD A-D
Communication
line (+) (Gray)
Communication
line (-) (Pink)
ML
B2
A1
T11
T12 T21 T22
Open
A2
A2
S14 S24
KM1 KM2
0 V
Motor controller
(operation command)
Input/Output Circuit and Applications
- F3SJ-B settings
- Muting system
- Does not use external device monitoring function
- G9SX-AD322-T15 settings
- Auto reset mode
- Using feedback loop
Feedback loop
KM1
KM2
KM3
KM4
+24 V
+24 V
T31 T32 T33 Y1
T41 T42
Open
Open Open
Control circuit
S34 S44 S54
L1
X1 X2
Model G9SX-AD322-T15
KM3 KM4
PLC,etc.
S1
: External test switch (connect 0 V if a switch is not required)
S2
: Lockout reset switch (connect to 24 V if a switch is not required)
KM1 to KM4 : Safety relay with force-guided contact (G7SA)
or magnetic contactor
M1, M2
: 3-phase motor
ML
: External indicator
PLC
: Programmable controller
(Used for monitoring -- not related to safety system)
*1. Also used for override input.
*2. Under muting system, connect to 0 V as the external device monitoring
cannot be used.
Wiring for manual reset mode
Feedback loop
KM1
KM2
S3
KM3
KM4
T31
T32 T33 Y1
S3 : Reset switch
S34
Motor controller
KM1
KM3
KM2
KM4