Input/Output Circuit and Applications
 Connecting a F3SJ-B to a G9SB-301-D
•Thin (22.5 mm thick)
F39-JD A-L
+24 VDC
Power
supply
0 V
Unblocked
Blocked
External test switch
Interlock reset switch
Emergency stop switch
Safety output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
PLC input 1 *
PLC input 2
PLC output
Use G9SB-301-B for auto reset with three N.O. and one N.C. contacts.
Use G9SB-200-D for manual reset with two N.O. contacts, or use G9SB-200-B for auto reset with two N.O. contacts.
For more information, visit OMRON's website at http://www.omron.com/
F3SJ-E/B
104
User's Manual
Communication
line (+) (Gray)
Communication
line (-) (Pink)
Feedback loop
A1
T21
A2
T11
T12
T22
T31
T32
TH
K1
K2
SA
K2
a
Control
Circuit
K1
a K2
G9SB-301-D
(S1)
(S2)
(S3)
* Auxiliary output gives inverted signal of
safety output.
- F3SJ-B settings
- Auto reset mode
- Does not use external device monitoring function
- G9SB-301-D settings
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
F39-JD A-D
PLC
IN1 IN2
*2
12
22
11
21
S3
KM1
KM2
*1
*1
13
23
33
41
K1
K1
K2
14 24 34 42
*1
*1
+24 V
KM1
KM2
*1 The G9SB-200-D (17.5 mm thick), with no 33-34 and 41-42, is also available.
*2 If an emergency stop switch is not used, connect safety output 1 to T12
terminal and safety output 2 to T22 directly.
S1
: External test switch (connect to 0V if a switch is not required)
S2
: Interlock reset switch
S3
: Emergency stop switch (force-opening contact)
(A165E, A22E)
S4
: Lockout reset switch (connect to 24V if a switch is not required)
KM1,KM2 : Safety relay with force-guided contact (G7SA)
or magnetic contactor
KM3
: Solid state contactor (G3J)
M
: 3-phase motor
PLC
: Programmable controller
(Used for monitoring -- not related to safety system)
OUT
KM3
KM1
KM2
M