Configuring Text Displayed On-Screen
11.5.1 Changing the Display of Direction Indicators
126
Siemens Building Technologies
Fire & Security Products
In this illustration, the black circle in the center represents the dome, the dotted circle
represents the pan axis, and the arrowheads represent panning the dome to the right.
Figure 45 represents pointing the dome precisely at 225° from North (Southwest) with a
tilt of 25° below the virtual horizon. Panning to the left points the dome towards the
South. Panning to the right points the dome towards the West.
S
SW
-25
Figure 45 Pointing the dome precisely Southwest with a tilt elevation of -25°
1.
Select On-Screen Text Display from the Dome Configuration Menu.
2.
Move the highlight to Direction Indicator.
3.
Change the setting.
Select On to display the direction information.
–
Select Off to prevent the direction information from displaying.
–
The default setting is Off.
4.
Select Exit. The Dome Configuration Menu appears.