4.
Reattach I/O board.
5.
Connect power to base.
6.
Set dome address (Figure 13).
Recessed at top of housing and eyeball assembly are three rotary address
switches. Address range is from 001 to 099.
Set switches from most significant bit (MSB) to least significant bit (LSB).
For example:
For address 066, set SW3 to 0, SW2 to 6,and SW1 to 6
Figure 13 Setting address switches
7.
Connecting the housing and eyeball assembly to the base (Fig. 14).
Align dimple on cap of dome with rib on mounting base.
Mate housing and eyeball assembly to base and turn it clockwise until you
hear a click.
8.
Wait a few seconds for dome to begin its homing routine. Homing routine
indicates that address was placed into dome memory and that dome is ready
for programming.
Fig. 14
Connecting the housing and eyeball assembly to the base
SW3
SW2
SW1
MSB
LSB
0
9 0
9 0
9
L A T C H
.
BE_CCDA1415-DN.doc
05.2004