10.6.2 Programming Privacy Zones

Siemens Building Technologies
Fire & Security Products
Configuring Alarms, Areas, Home, Privacy Settings and Presets
Maximum Allowed Number of Zones Defined
Pressing Focus Far returns to the Program Privacy Zones screen. To program a
new zone, you must delete at least one of the eight existing Privacy Zones:
Areas of the Privacy Zone may be exposed during rapid pan / tilt movements of
IMPORTANT
the dome. To compensate for this limitation, you may want to program the
Privacy Zone to be 20 to 25% larger than the area you want to mask.
1.
Select Alarms/Areas/Home/Presets/PZ from the Dome Configuration Menu.
2.
Select Privacy Zones.
3.
The Program Privacy Zones screen appears. Select Add Privacy Zone.
4.
Use the Pan/Tilt control to position the arrows over the boundary point. Press
Zoom to create.
5.
Repeat step 4 to create boundary points 2 and 3.
Tip:
Remember, if the arrows are blinking, you are not in a valid target area. Only select a point if the
arrows are not blinking.
6.
After the third boundary point is created, the fourth boundary point is
automatically calculated. The new Privacy Zone appears on the screen. To
program additional Privacy Zones, repeat steps 3 through 5. When finished,
continue with step 7.
7.
Select Exit to return to Alarms/Areas/Home/Presets/PZ screen.
8.
When the Alarms/Areas/Home/Presets/PZ screen appears, select Exit.