Siemens CCDA1415-DN Instruction Manual page 23

Day/night dome system
Table of Contents

Advertisement

Siemens Building Technologies
Fire & Security Products
Fig. 12
Electrical connections
Connect alarm output cable, if used, to P3 connector.
Pin
Designation
1
12 V DC (100 mA max.)
2
12 V DC (100 mA max.)
3
Output P0 (40 mA sync. Max.)
4
Output P1 (40 mA sync. Max.)
5
Output P2 (40 mA sync. Max.)
6
Output P3 (40 mA sync. Max.)
7
Ground
8
Ground
Connect alarm input cable, if used, to P4 connector.
Pin
Designation
1
Alarm 3 input (3.5 mA sink)
2
Alarm 2 input (3.5 mA sink)
3
Alarm 1 input (3.5 mA sink)
4
Alarm 0 input (3.5 mA sink)
5
Ground
6
Ground
Connect power to P7 connector.
Pin
Designation
1
24 V AC
2
Ground
3
24 V AC
Pin 1
Pin 1
P3
P7
P4
P8
JW1
I/O Board
Pins
Function
Unterminated
1-2
2-3
Terminated
Indoor Installation
Pin 1
Pin 1
P1