Indoor Installation
90
Siemens Building Technologies
Fire & Security Products
Siemens RS422/RS485 data connections
Pin
Designation
1
RS422 Data In High (+)
2
RS422 Data In Low (–)
3
RS422 Data Out High (+)
4
RS422 Data Out Low (–)
5-6
must be connected using a jumper cable!
IMPORTANT
If the Siemens protocol is used, the SensorNet input must be jumpered!
The following interface parameters are applicable for the Siemens protocol
RS422/RS485:
Data rate in baud
19,200 bits/s
Data format
Start bit 1
Data bit 8
Parity
Stop bit 1
Table 3
Interface parameters Siemens RS422/RS485
SensorNet RS485 data connections
Pin
Designation
1-4
not used
5
SensorNet (unshielded)
6
SensorNet (unshielded)
0
from the controller
to the next dome