Siemens CCBS1337-LP Instruction Manual

Siemens CCBS1337-LP Instruction Manual

1/3 inch super high-res day-night camera

Advertisement

1/3 inch Super High-Res
Day-Night Camera
CCBS1337-LP
CCBS1337-MP

Instruction Manual

Fire Safety & Security Products
Siemens Building Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Siemens CCBS1337-LP

  • Page 1: Instruction Manual

    1/3 inch Super High-Res Day-Night Camera CCBS1337-LP CCBS1337-MP Instruction Manual Fire Safety & Security Products Siemens Building Technologies...
  • Page 2 Dear Customer By selecting this SIEMENS product, you have chosen a professional device that guarantees the highest possible quality and reliability. We would like to thank you...
  • Page 3: Table Of Contents

    ALARM DELAY ..................22 7.2.14.6 ALARM TEXT..................22 7.2.14.7 CHROMA ....................22 7.2.14.8 CAMERA TEXT..................22 7.2.15 REMOTE....................23 7.2.15.1 MODEL ....................23 7.2.15.2 ADDRESS....................23 7.2.15.3 BAUD RATE...................23 7.2.15.4 PROTOCOL ...................24 7.2.15.5 SOFT VER: ....................24 7.2.15.6 PATTERN ....................24 Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 4 7.2.16 NEXT/ BACK ...................24 7.2.17 EXIT ......................24 7.2.18 CANCEL....................24 7.2.19 DEFAULT ....................24 Index .......................25 Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 5: General Information

    To ensure normal operation and to avoid EMC problems, the product must be installed according to the currently valid EMC installation guidelines. To meet the CE norms, enclosed EMI-cores should be applied to the Y/C and power cable (see chapter 7.1). Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 6: Manufacturer's Declaration Of Conformity

    EN 55022:1998 Class B EN 50130-4:1998 EN 61000-3-2 A2: 1998 EN 61000-3-3: 1995 The EU certificate of conformity is available for official inspection and is held at: Siemens Building Technologies SBT FSP DE Siemensallee 84 76187 Karlsruhe, Germany Ordering Data Designation Order No.
  • Page 7: General Guidelines

    This is a fixed pattern which may appear over the entire monitor screen when the camera is operated at a high temperature. Jagged picture When viewing stripes, straight lines, or similar patterns, the image on the screen may appear jagged. Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 8: Technical Specifications

    6 area selectable: Center 1, Center 2, Up Half, Low Half, Middle Low, Middle High Privacy zone 8 blocks (max) D/N mechanical Dual moving OLPF/glass D/N mode AUTO, MAUNAL, COLOR, MONO Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 9 5 control keys on the side panel of camera Default settings Default setting restored by pushing the DEFAULT button Remote control RS-485 Alarm IN Alarm OUT NC or NO selectable Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 10: Camera Parts & Connections

    Camera Parts Back focus adjustment ring ① Back focus lock screw ② Tripod mount hole ③ IRIS connector ④ Power indicator ⑤ Video output ⑥ Power cord (or power terminal) ⑦ Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 11: Connector Pin Definitions

    1. Damp- 2. NC 2. Damp+ 3. VIDEO 3. Drive + 4. GND 4. Drive- Y/ C terminal Y (luminance, 1 Vpp, 75 ) C (chrominance, 0.3 Vpp (burst), 75 ) Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 12: Osd Setting Hierarchy

    R: 0~31 B: 0~31 GAMMA 0.45 APERTURE HIGH MIRROR PRIVACY ZONE OPTION ALARM ALARM OUT ALARM BLEMISH DET BACKFOCUS DELAY FUNC CHROMA ALARM TEXT CAMERA TEXT REMOTE NEXT/ BACK DEFAULT CANCE EXIT (P2) Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 13: Installing The Camera

    Select ENTER on the OSD; the menu will appear on the display and will disappear after 30 seconds if no action occurs. The shaded setting area means an item is selected; it keeps blinking. Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 14: D/N Mode

    When set to this mode, the camera will remain in color mode. MANUAL When set to this mode, the camera will be switched to color or B/W mode manually according to a signal received at a terminal on the rear panel. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 15: D/N Level

    We recommend using the D/N mode “MANUAL” when the camera is used with discrete IR illumination in order to prevent the continual switching between color and B/W mode that might occur with the D/N mode “AUTO” Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 16: Exposure

    This function sets the high-speed electronic shutter (AUTO to 1/100K sec). Move the cursor to the position shown in Fig. 5. Using the LEFT/ RIGHT button, select a shutter speed from 1/50 to 1/100K. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 17: Gain

    The camera is in the line lock mode; you can adjust the phase angle from 0 ~ 300° accordingly. The default is 0° . NOTE: For DC power models, the SYNC will be set automatically to INT mode. Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 18: Blc

    APERTURE MIRROR PRIVACY ZONE <OFF> OPTION <SET> REMODE <SET> NEXT EXIT CANCEL DEFAULT Fig. 9 WHITE BAL This function is for setting the white balance mode (ATW1, ATW2, and manual mode). Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 19: Gamma

    This function is for setting the picture sharpness. (LOW, MID, HIGH) Move the cursor to the position shown in Fig. 11. Use the LEFT/ RIGHT button to choose HIGH, MID or LOW. Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 20: Mirror

    1 SET CLR BACK CLEAR ALL In the submenu, the user can select ON or OFF for the privacy zone and set up to 8 blocks at any position on the screen. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 21: Option

    N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 : < > □ - . , ; x / BACK CLEAR Fig. 16 Alarm menu Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 22: Alarm Out

    CAMERA TEXT Use ENTER to access the submenu. When you leave the OSD menu, the text will be shown on the display. You can position the text anywhere on the screen. Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 23: Remote

    7.2.15.3 BAUD RATE This function is used to set the camera’s remote baud rate in the range from 2400 to 19200 bits per second. Siemens Building Technologies Fire Safety & Security Products 03. 2005...
  • Page 24: Protocol

    Select one of the 3 various protocols, depending on the type of remote connectivity, for remote OSD control camera setup: SIEMENS-B: When using the camera with bi-directional remote control under remote software and PC (remote software provides full parameter setup).
  • Page 25: Index

    5 EU Directive, 6 shutter, 15 EXIT, 23 SYNC, 16 exposure, 15 synchronization, 16 function setting, 13 Transportation, 7 gain, 16 WHITE BAL, 17 GAMMA, 18 white balance, 17 MIRROR, 19 Siemens Building Technologies Fire Safety & Security Products 03.2005...
  • Page 26 Issued by © 2005 Copyright by Siemens Building Technologies Siemens Building Technologies AG Fire & Security Products GmbH & Co. oHG Data and design subject to change without notice. D-76181 Karlsruhe Supply subject to availability. Printed in the Federal Republic of Germany www.sbt.siemens.com/fsp...