Bunn IMIX-3S+ Installation & Operating Manual page 24

Table of Contents

Advertisement

Adjust soluble tank temperature
TANK TEMP XXX°
(190° F maximum)
(-)
EXIT
(+)
Adjust minimum soluble tank ready tem-
READY TEMP XXX°
perature for lockout (185° maximum)
(-)
EXIT
(+)
Set espresso tank temperature.
ESPRSO TEMP XXX°
(-)
EXIT
(+)
Set espresso tank ready temperature.
ESPRSO READY XXX°
Tank temp. must reach this to enable
(-)
EXIT
(+)
brewing if brew lockout is set.
Takes you to the STRENGTH ADJUST
STRENGTH ADJUST
sub-menu to adjust soluble hopper
EXIT
YES
speeds and grinder times.
Takes you to the CALIBRATION
CALIBRATION
sub-menu.
EXIT
YES
Takes you to the SET BEVERAGE
SET BEVERAGE SZ
SIZE sub-menu to adjust beverage
EXIT
YES
size.
Takes you to the SET ESPRESSO
SET ESPRSO SHOTS
SHOTS sub-menu to set up espresso
EXIT
YES
shots.
Takes you to the LOCK/DISABLES
LOCKS/DISABLES
sub-menu.
EXIT
YES
Takes you to the DIAGNOSTICS menu
DIAGNOSTICS
to test components.
EXIT
YES
Takes you to the FACTORY DEFAULTS
FACTORY DEFAULTS
sub-menu to enable restoring factory
NO
YES
defaults.
Use +/- buttons to increase or decrease
LEFT HOPPER STR
powder hopper speed. This menu
(-)
##
(+)
repeats for middle and right hopper.
Pressing any dispense button will run
TEST LEFT HOPPER
hopper for 10 seconds, at speed set in the
PRESS DISPENSE
menu above. This allows a catch test.
Pressing any dispense button will run
SM ESP GRIND TIME
grinder for the small espresso pro-
(-)
#.# sec
(+)
grammed time. This allows a catch test.
Menu repeats for large espress grind time.
Pressing any dispense button will run
TEST SM GRIND
grinder for the small espresso programmed
DISPENSE TO TEST
time. This allows a catch test. Menu
repeats for large espresso grind time.
Allows applicable data to be displayed in
SELECT UNITS
English or Metric units.
ENG EXIT METRIC
Sets threshold for refill probe on soluble
0
REFILL 155
water tank. Allows adjustment for different
(-)
EXIT
(+)
water conditions.
GLOSSARY
AUGER DELAY
(-)
.50 sec
WHIPPER DELAY
(-)
.00 sec
CAL HOT WATER
PRESS DISPENSE
CAL LFT PWDR VLV
PRESS DISPENSE
CAL RT PWDR VLV
PRESS DISPENSE
PUMP START DELAY
(-)
.# sec
ESP THRESHOLD
(-)
###
PSTN HOME THRESOLD
(-)
###
CAL BEAN HOPPER
EXIT
PRE-HEAT ESP GRP
NO
EXIT
SET PRE-HEAT TIME
(-)
###min
ESPR TANK: ###F
PWDR TANK: ###F
24
Delays the start of the hopper mo-
tors after dispense valve opens. This
(+)
prevents soluble powder from entering
mixing chamber ahead of hot water.
This delays the start of the whipper
motors after the dispense valve opens.
(+)
Pressing any dispense button opens
the hot water valve for ten seconds.
This allows the valve to be adjusted for
the proper flow rate.
Pressing any dispense button opens
the left hot water valve for ten
seconds. This allows the valve to be
adjusted for the proper flow rate.
Pressing any dispense button opens
the right hot water valve for ten
seconds. This allows the valve to be
adjusted for the proper flow rate.
This delays the start of the espresso
pump after the espresso valve opens.
(+)
This sets the current level at which
the piston sees, to signal the motor to
(+)
shut down in the wipe position.
This sets the current level at which
the piston sees, to signal the motor to
(+)
shut down in the home position.
This calibrates the photo sensor on
the bean hopper by detecting the am-
YES
bient light with the hopper empty, then
setting a threshold for signaling when
the hopper is empty.
This asks if you want to enable
pre-heating of the espresso group, if
YES
espresso has not been brewed within
"X" amount of time. For espresso
shots only - not for specialty drinks.
Sets the amount of time (in minutes),
that if exceeded, will automatically go
(+)
into pre-heat routine, if an espresso
shot is selected to be dispensed.
Live temperature display, or probe
fault codes.