2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(
C)
o
(DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated heating
condition(
C)
o
(DB/WB)
Indoor
Outdoor
20/15
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.

2.5 Noise Curve

Indoor side noise when blowing
45
40
35
30
25
Supper High
High
Indoor fan motor rotating speed
Technical Information
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
0.8 to 1.0
12K
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
2.2 to 2.4
12K
Middle
Low
Inlet and outlet pipe
temperature of heat
Fan speed of
exchanger
T1 (
C)
T2 (
C)
o
o
12 to 15
65 to 38
11 to 14
64 to 37
Inlet and outlet pipe
temperature of heat
Fan speed of
exchanger
T1 (
C)
T2 (
C)
o
o
35 to 63
2 to 5
35 to 65
2 to 5
Outdoor side noise when Compressor speed changed
55
50
45
20
30
40
Compressor Speed(rps)
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
50
60
70
Compressor
frequency
(Hz)
54
60
Compressor
frequency
(Hz)
62
66
09K
12K
75
5