Gree GWH09RB-K3DNA3G Service Manual page 38

Table of Contents

Advertisement

Service Manual
Malfunction
Dual-8
NO.
Name
Code
Display
Malfunction of
phase current
44
detection
U1
circuit for
compressor
Malfunction of
voltage
45
U3
dropping for
DC bus-bar
Malfunction
of complete
46
U5
units current
detection
The four-way
47
valve is
U7
abnormal
Zero-
crossing
48
U9
malfunction of
outdoor unit
Malfunction of
zero-cross
49
U8
detection
circuit
Compressor
50
running
The
temperature
51
for turning
on the unit is
reached
Frequency
limiting
52
(module
temperature)
Installation and Maintenance
Display Method of Indoor Unit
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s)
Operation
Cool
Heating
Indicator
Indicator
Indicator
Display Method of Outdoor
Unit
Indicator has 3 kinds of
display status and during
blinking, ON 0.5s and OFF
0.5s
Yellow
Red
Green
Indicator
Indicator
Indicator
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, the compressor will
stop while indoor fan will
operate;
During heating operating,
the complete unit will stop
operation.
If this malfunction occurs
during
heating operation, the complete
unit will stop operation.
During cooling operation,
compressor will stop while
indoor fan will operate; during
heating,the complete unit will
stop operation.
The complete unit stops
OFF 1S
and blink
once
OFF 1S
and blink
8 times
OFF 1S
and blink
11 times
A/C status
Possible Causes
Replace outdoor control panel AP1
Supply voltage is unstable
Theres circuit malfunction on
outdoor units control panel AP1,
please replace the outdoor units
control panel AP1.
1.Supply voltage is lower than
AC175V;
2.Wiring terminal 4V is loosened or
broken;
3.4V is damaged, please replace
4V.
Replace outdoor control panel
1.Power supply is abnormal;
2.Detection circuit of indoor
control mainboard is abnormal.
AP1
35