Service Manual
Steps
9. Remove press plate of connecting pipe
Remove the screws of the press plate of
a
connecting pipe.
b
Remove press plate of connecting pipe.
10. Remove the evaporator
Remove the screws at the joint of the
a
evaporator and bottom case.
Installation and Maintenance
Procedure
Pipe Clamp
Auxiliary piping
63