OAM-DUAL TE
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
WARNING
may result in serious injury or death.
Failure to follow the instructions that accompany this indication and improper handling
CAUTION
may result in injury and/or damage to property.
NOTE
Pay special attention to sections with this symbol.
It is required to check the operation manual if this symbol is shown on the product.
NOTE
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic
sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the
building owner/operator on proper operation of the door and the product.
7. The product settings can only be changed by an installer or service engineer.
When changed, the changed settings and the date shall be registered in the maintenance logbook
accompanying the door.
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Vibration
Objects
Specifications
Model
: OAM-DUAL TE
Cover color
: Black
Mounting height
: 2.0 to 3.5 m (6'7" to 11'6")
Detection area
: See Detection area
Detection method
: Active infrared reflection (*1)
Microwave Doppler effect
Transmitter frequency
: 24.125 GHz
Transmitter radiated power
: < 20 dBm
Depth angle adjustment
: AIR area -6 to +6°
Radar area +25 to +45°
Power supply (*2)
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
Power consumption
: < 2.5 W (< 4 VA at AC)
Operation indicator
: See Operation indicator table
Output hold time
: < 500 ms
Response time
: < 300 ms
Operating temperature
: -35 to +55°C (-31 to 131°F)
Operating humidity
: < 80 %(non-condensing)
Noise level
: < 70 dBA
Table 1
Relay output
Voltage output Frequency output
Cat.
2 (EN ISO13849-1:2015)
AIR
part
PL
d (EN ISO13849-1:2015)
Cat.
2 (EN ISO13849-1:2015)
Radar
part
PL
d (EN ISO13849-1:2015)
Operation indicator table
Status
Operation indicator color
Warm-up
Stand-by (Installation mode)
Stand-by (Service mode)
Yellow & Green blinking
Stand-by (Operation mode)
BLUEZONE (Lookback) detection (*4)
2nd row detection
3rd row detection
Radar detection
Communication Test output
Turn off 500 ms (*5)
Setting error
Red & Green blinking
Signal saturation
Slow Green blinking
Sensitivity too low(or Sensor failure)
Fast Green blinking
NOTE
The specifications herein are subject to change without prior notice due to improvements.
*1 : Active infrared reflection has a presence detection function.
*2 : The sensor has to be connected to a door system which has a SELV circuit.
*3 : Overcurrent protection with less than 2 A.
*4 : See BLUEZONE (Lookback) area
*5 : LED will be turned off approx. 500 ms when the sensor Test output signal works well.
BLUEZONE (Lookback) area
When dipswitch 15 is set to "ON", the BLUEZONE (Lookback) area, that provides extra safety over the threshold is
activated. In case the BLUEZONE (Lookback) function is not required, set dipswitch 15 to "OFF".
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
BLUEZONE
(Lookback)
2nd row
3rd row
Outer dimensions and part names
125(4 15/16")
36(1 7/16")
43(1 11/16")
267(10 1/2")
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Width adjustment screws
5927902 OCT 2019
Original instructions
WARNING
Danger of electric shock
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Reflection
Activation output
: Choose the output mode
- Relay output
- Voltage output
- Frequency output
(See Installation 2)
Safety output
: Form A relay 50 V 0.3 A Max.
Test input
: Opto coupler
Voltage 5 to 30 VDC
Current 6 mA Max. (30 VDC)
IP rate
: IP54
: See Table 1
Category
Performance level
: See Table 1
ESPE
: Type 2
Weight
: 270 g (9.5 oz)
Accessories
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10")(*3)
1000 ms
Yellow blinking
Yellow
Green
Blue
Red blinking
Red
Orange
BLUEZONE
(Lookback)
2nd row
3rd row
38(1 1/2")
(2)
(1)
(3)
(4)
(5)
[mm(inch)]
(5) Depth angle adjustment screw
(9) Detection window
(6) Function switch
(10) Area adjustment tool
(7) Radar sensitivity potentiometer
(8) Dipswitches
Complied standards and extract from EC declaration of conformity
ENGLISH
DIN 18650-1:2010 Chapter 5.7.4 ESPE Chapter 5.8.2.4.3
EN 16005:2012/AC:2015 Chapter 4.6.8 and Annex C , Chapter 4.7.2.3
EN 61000-6-2:2005/AC:2005
EN 61000-6-3:2007 +A1:2011/AC:2012
EMC Directive 2014/30/EU
Machinery Directive 2006/42/EC
Notified Body 0044 : TÜV NORD CERT GmbH Langemarckstr. 20 45141 Essen Germany
For technical document, see European Subsidiary
NI-0092-1
Detection area
A
BLUEZONE
(Lookback)
2nd row
3rd row
1.0
(3'3")
2.0
(6'7")
2.0
(6'7")
AIR emitting area
The chart shows the values at depth angle +6°.
A
2.00 (6'7")
2.20 (7'3")
B
0.05 (2")
0.06 (2")
C
0.07 (3")
0.08 (3")
D
0.23 (9")
0.25 (10")
E
0.35 (1'2")
0.39 (1'3")
F
0.59 (1'11")
0.65 (2'2")
G
1.21 (3'12")
1.33 (4'4")
H
1.86 (6'1")
2.05 (6'9")
I
2.52 (8'3")
2.78 (9'1")
AIR detection area
To comply with EN 16005, make sure that the detection area is within the values of the chart below.
A
2.00 (6'7")
2.20 (7'3")
X
0.23 (9")
0.25 (10")
G
1.02 (3'4")
1.12 (3'8")
I*
2.41 (7'11")
2.65 (8'8")
The values above are those of the AIR detection area when tested referring to the test conditions of EN 16005.
(The emitting area is as shown in AIR emitting area above.)
* When installed at higher than 3.0 m(9'10"), EN 16005 requirements are fulfilled only within the area width "I" of 3.6 m(11'10").
NOTE
The actual detection area may become smaller depending on the ambient light, the color/material of the
object or the floor as well as the entry speed of the object. The sensor may not be activated when the
entering speed of the object or a person is slower than 50 mm/s or faster than 1500 mm/s.
Installation
1. Mounting
a. Place the mounting template at the desired mounting position.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
b. Drill two mounting holes of ø3.4 mm (ø1/8").
c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").
d. Remove the mounting template.
e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Header
Sensor
Y
X
H
Door
1000 ms
Floor
NOTE
Make sure not to mount the sensor lower than the bottom of header.
Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there
may be no detection area around the threshold. Install the sensor as low as possible on the header.
2. Wiring
Wire the cable to the door controller.
WARNING
Danger of electric shock
Before starting the procedure,
make sure that the power is
turned OFF.
When passing the cable
through the hole, do not tear
the shield otherwise it may
cause electric shock or
breakdown of the sensor.
3. Turn ON the power
a. Plug the connector.
b. Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See Adjustments 4. Dipswitch settings)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
(10)
When turning the power ON or after adjusting the settings, do not enter the detection area for more than
10 s in order to enable the presence detection. Do not touch the dipswitches before turning the
power ON, otherwise an error occurs. After changing the dipswitch and/or potentiometer settings, make
sure to push the function switch for 2 s.
(9)
(6)
(7)
(8)
4. Mounting the housing cover
Place the housing cover.
If wiring is to be exposed,
break the knockout.
[m(feet,inch)]
Mounting
B
surface
D E
C
F
X
G
H
I
1.0
0
1.0
2.0
(3'3")
(3'3")
(6'7")
[m(feet,inch)]
2.50 (8'2")
2.70 (8'10")
3.00 (9'10")
3.50 (11'6")
0.07 (3")
0.07 (3")
0.08 (3")
0.09 (4")
0.09 (4")
0.10 (4")
0.11 (4")
0.12 (5")
0.28 (11")
0.31 (1')
0.34 (1'1")
0.39 (1'3")
0.44 (1'5")
0.48 (1'7")
0.53 (1'9")
0.61 (2')
0.74 (2'5")
0.80 (2'7")
0.89 (2'11")
1.03 (3'5")
1.51 (4'11")
1.63 (5'4")
1.81 (5'11")
2.11 (6'11")
2.32 (7'7")
2.51 (8'3")
2.79 (9'2")
3.25 (10'8")
3.15 (10'4")
3.40 (11'2")
3.79 (12'5")
4.42 (14'6")
[m(feet,inch)]
Test conditions required by EN 16005
3.00 (9'10")
Floor : Grey paper
0.34 (1'1")
Detection object : EN 16005 CA reference body
1.53 (5')
Sensitivity : Middle
Speed of detection object : 50 mm/s
3.60 (11'10")
H : Height from the floor to the bottom of the header
(The mounting height is "H + Y".)
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
Maximum mounting distance (Y)
H
2.00 (6'7")
2.30 (7'7")
2.50 (8'2")
X
0
0.05 (2")
0.13 (5")
0.13 (5")
0.13 (5")
0.10 (4")
0.11 (4")
0.12 (5")
0.12 (5")
0.15 (6")
0.10 (4")
0.10 (4")
0.11 (4")
0.20 (8")
-
0.09 (4")
0.10 (4")
0.25 (10")
-
-
0.09 (4")
0.30 (12")
-
-
CAUTION
Risk of getting caught
Relay output
Power supply
Activation output
(Relay,Freq.)
Safety output
Test input
Activation output
(Volt.)
1
12 to 24 VAC ±10 % / 12 to 30 VDC ±10 %
Form A relay
2
50 V 0.3 A Max.
3
Form A relay 50 V 0.3 A Max.
4
Opto coupler / Voltage: 5 to 30 VDC
(+)
5
(-)
WARNING
Do not use the sensor without the cover. When using the cable knockout,
install the sensor indoors or use the rain cover (Separately available)
otherwise electric shock or breakdown of the sensor may occur.
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
EN 12978:2003 +A1:2009
EN ISO 13849-1:2015
EN ISO 13849-2:2012
AutSchR
A. Maekawa
General Manager
OPTEX CO., LTD.
Quality Control Dept.
AIR
Mounting height : 2.2 m (7'3")
Angle adjustment : +6°
Sensitivity : Middle
: Emitting spots
: Emitting spots
(can be eliminated)
: Detection area
Radar
Mounting height : 2.2 m (7'3")
Vertical adjustment : +35°
Sensitivity : High
Area width : Wide
Speed of detection object
: 50 mm/s
: Detection area
[m (feet,inch)]
2.80 (9'2")
3.00 (9'10")
3.50 (11'6")
No limit
0.14 (6")
0.14 (6")
0
0.12 (5")
0.12 (5")
0
0.11 (4")
0.11 (4")
0
0.10 (4")
0.10 (4")
0
0.09 (4")
0.09 (4")
0
-
-
-
0
Voltage output
Frequency output
1.White
1
2.Brown
3.Green
2
4.Yellow
Polarity free
5.Pink
3
6.Blue
7.Red
4
8.Black
9.Grey/Pink (+)
5
10.Red/Blue (-)
Frequency output
100 Hz ±10 %
Voltage output 3.2 V
@10 mA
4.5 V Min. (no load)
Danger of electric shock

Advertisement

loading

Summary of Contents for Optex OAM-DUAL TE

  • Page 1 The values above are those of the AIR detection area when tested referring to the test conditions of EN 16005. (The emitting area is as shown in AIR emitting area above.) Model : OAM-DUAL TE Activation output : Choose the output mode * When installed at higher than 3.0 m(9'10"), EN 16005 requirements are fulfilled only within the area width "I"...