Download Print this page
Optex OA-FLEX LITE Quick Start Manual

Optex OA-FLEX LITE Quick Start Manual

Advertisement

Quick Links

OA-FLEX LITE
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
WARNING
may result in serious injury or death.
Failure to follow the instructions that accompany this indication and improper handling
CAUTION
may result in injury and/or damage to property.
NOTE
Pay special attention to sections with this symbol.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic
NOTE
sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the
building owner/operator on proper operation of the door and the product.
7. The product settings can only be changed by an installer or service engineer.
When changed, the changed settings and the date shall be registered in the maintenance logbook
accompanying the door.
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Vibration
Objects
Specifications
: OA-FLEX LITE
Model
Cover color
: Silver/Black
: 2.0 to 3.0 m (6'7" to 9'10")
Mounting height
: See Detection area
Detection area
: Active infrared reflection
Detection method
: Depth : -6° to +10°
Area angle adjustment
Width : ±7°
(2 clicks with 3.5°every click-Left/Right)
Power supply (*1)
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
Power consumption
: < 2.0 W (< 5 VA at AC)
: See Operation indicator table
Operation indicator
Output hold time
: Approx. 500 ms
: < 300 ms
Response time
Operating temperature
: -20 to +55°C (-4 to 131°F)
: < 80 %(non-condensing)
Operating humidity
Noise level
: < 70 dBA
: Form C relay 50 V 0.3 A Max.
Output
(Resistance load)
: IP54
IP rate
Weight
: 220 g (7.8 oz)
: 1 Quick Guide
Accessories
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10")(*2)
Operation indicator table
Status
Operation indicator color
Stand-by
1st row detection
2nd row detection
3rd - 5th row detection
Signal saturation
Slow Green blinking
Sensitivity too low
Fast Green blinking
NOTE
The specifications herein are subject to change without prior notice due to improvements.
*1 : When using this sensor, the sensor has to be connected to a door system which has the SELV circuit.
*2 : Overcurrent protection with less than 2A.
Dimensions and part names
245(9 5/8")
125(4 15/16")
36(1 7/16")
43(1 11/16")
(2)
(1)
(3)
(4)
(5)
WARNING
Danger of electric shock
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Reflection
1000 ms
Green
Red blinking
Red
Orange
37(1 7/16")
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Dipswitches
(5) Area angle adjustment screws
(6) Area width adjustment screws
(7) Detection window
(8) Area adjustment tool
(8)
(6)
(7)
[mm (inch)]
ENGLISH
5933110 NOV 2022
Detection area
Charts show the values in the following area angle adjustment settings.
Depth
: 2°
Width
: 0°
: Emitting spots
: Emitting spots
(can be eliminated)
: Detection area
Emitting area
A
2.00 (6'7")
2.30 (7'7")
B
0.26
(10")
0.30
C
0.53
(1'9")
0.61
D
0.80
(2'8")
0.92
E
1.14
(3'9")
1.32
F
1.53
(5')
1.76
G
0.13
(0'5")
0.15
H
0.96
(3'2")
1.10
I
1.55
(5'1")
1.78
J
2.13
(7')
2.45
Installation
1. Mounting
a. Place the mounting template at the desired mounting position.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
b. Drill two mounting holes of ø3.4 mm (ø1/8").
c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").
d. Remove the mounting template.
e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Header
Sensor
Y
X
H
Door
Floor
Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there
may be no detection area around the threshold. Install the sensor as low as possible on the header.
1000 ms
2. Wiring
Wire the cable to the door controller.
Sensor
Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield otherwise it may cause electric shock or breakdown
of the sensor.
3. Turn ON the power
a. Plug the connector.
b. Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See Adjustments 3. Dipswitch settings)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 s in order to enable the presence detection. Do not touch the dipswitches before turning the
power ON, otherwise an error occurs.
4. Mounting the housing cover
Place the housing cover. If wiring is to be exposed, break the knockout.
Knockout
Mounting
surface
1st row
Motion/Presence
2nd row
detection
3rd row
4th row
Motion detection
5th row
[m(feet,inch)]
NOTE
2.50 (8'2")
3.00 (9'10")
(1')
0.33
(1'1")
0.39
(1'4")
The actual detection area may become smaller
(2')
0.66
(2'2")
0.79
(2'7")
depending on the ambient light, the color/material of the
object or the floor as well as the entry speed of the
(3')
1.00
(3'3")
1.20
(3'11")
object.
(4'4")
1.43
(4'8")
1.72
(5'8")
The sensor may not be activated when the entering
speed of the object or a person is slower than 50 mm/s
(5'9")
1.91
(6'3")
2.29
(7'6")
or faster than 1500 mm/s.
(0'6")
0.16
(0'6")
0.19
(0'8")
(3'7")
1.20
(3'11")
1.44
(4'9")
(5'10")
1.93
(6'4")
2.32
(7'7")
(8')
2.66
(8'9")
3.20
(10'6")
H : Height from the floor to the bottom of the header
(The mounting height is "H + Y".)
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
Maximum mounting distance (Y)
H
2.00 (6'7")
2.30 (7'7")
X
0
0.14 (6")
0.14 (6")
0.05 (2")
0.13 (5")
0.13 (5")
0.10 (4")
0.11 (4")
0.11 (4")
0.15 (6")
0.10 (4")
0.10 (4")
0.20 (8")
0.09 (4")
0.09 (4")
0.25 (10")
0.07 (3")
0.07 (3")
0.30 (12")
0.06 (2")
0.06 (2")
NOTE
Make sure not to mount the sensor lower than the bottom of header.
CAUTION
Risk of getting caught
Grey
Grey
White
Yellow
Green
WARNING
Danger of electric shock
WARNING
Do not use the sensor without the cover. When using the cable knockout,
install the sensor indoors or use the rain cover (Separately available)
otherwise electric shock or breakdown of the sensor may occur.
A
G
B C
D
E
F
H
I
J
[m (feet,inch)]
2.50 (8'2")
3.00 (9'10")
0.14 (6")
0
0.13 (5")
0
0.11 (4")
0
0.10 (4")
0
0.09 (4")
0
0.07 (3")
0
0.06 (2")
0
Power
Power
COM.
N.O.
N.C.
Danger of electric shock

Advertisement

loading

Summary of Contents for Optex OA-FLEX LITE

  • Page 1 3.20 (10'6") Exhaust Vibration Objects Reflection Specifications Installation : OA-FLEX LITE Model 1. Mounting Cover color : Silver/Black a. Place the mounting template at the desired mounting position. : 2.0 to 3.0 m (6'7" to 9'10") Mounting height (When setting the detection area close to the door, mount the sensor according to the chart below.)
  • Page 2 (Ghosting). When this switch is set to "ON", the actual detection Immunity area may occur smaller. Contact Europe, Middle-East and Africa Subsidiary OPTEX TECHNOLOGIES B.V. Henricuskade 17, 2497 NB The Hague, The Netherlands www.optex-europe.com Tel : +31(0)70 419 41 00 5 rows...